York AY012MA321 Technical Manual

York AY012MA321 Technical Manual

Split-system air conditioners 13 seer 1 thru 3 nominal tons, 1 ph

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
13 SEER
AY012MA321 THRU 036
(1 THRU 3 NOMINAL TONS, 1 PH)
R
P
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
LISTED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ari.org/aridirectory.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a versa-
tile system of air conditioning. It is designed to be custom- matched
with one of UPG's complete line of evaporator sections, each
designed to serve a specific function.
WARRANTY
5-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS -
aluminum microchannel tubing and enhanced aluminum fins for
increased efficiency and corrosion protection.
COIL PROTECTION -
Coils are protected from damage by a
polymer mesh applied between the coil face, and a coated steel coil
guard.
PROTECTED COMPRESSOR -
protected against high pressure and temperature. This is accom-
plished by the simultaneous operation of high pressure relief valve
and a temperature sensor which protects the compressor if undesir-
able operating conditions occur. A liquid line filter-drier further pro-
tects the compressor.
DURABLE FINISH -
The cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better paint-to-steel
bond, which resists corrosion and rust creep. Special primer formulas
and matted champagne finish insure less fading when exposed to
sunlight.
LOWER INSTALLED COST -
reduced by easy power and control wiring connections. The small
base dimension means less space is required on the ground or roof.
TOP DISCHARGE -
The warm air from the top mounted fan is
blown away from the structure and any landscaping. This allows
compact location on multi-unit applications.
LOW OPERATING SOUND LEVEL -
ries the normal operating noise away from the living area. The rigid
top panel effectively isolates any motor sound. Isolator mounted
compressor and the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE -
Long life permanently lubricated motor-
bearings need no annual servicing.
EASY SERVICE ACCESS -
tions and a single panel covering the electrical controls make for
easy servicing of the unit.
SECURED SERVICE VALVES -
valves are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
U.L. AND C.U.L. LISTED -
Certified in accordance with the Unitary Small Equipment certification
program, which is based on ARI Standard 210/240.
246814-YTG-D-0606
The coil is constructed of
Compressors are internally
Installation time and costs are
The upward air flow car-
Fully exposed refrigerant connec-
Secured re-usable service
Approved for outdoor application.

Advertisement

Table of Contents
loading

Summary of Contents for York AY012MA321

  • Page 1 Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ari.org/aridirectory. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2: Unitary Products Group

    2. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. AY012MA321 AY018MA321...
  • Page 3 UC36B3X — UC36C3X — UC42B3X — UC42C3X — UC48C3X — UC48D3X — Unitary Products Group AY012MA321 AY018MA321 AY024MA321 1TVM2A1 1TVM2A1 1TVM2A1 2 - 14 2 - 14 3 - 6 TXV Kit3 - Additional Charge, Oz — — — —...
  • Page 4: Table Of Contents

    3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set. AY012MA321 AY018MA321 AY024MA321...
  • Page 5 MV12B AY030MA321 MV16C MV16C MV16C MV16C MV12B MV12B MV16C MV16C AY036MA321 MV16C MV16C MV20D 8,10,15,18,20,25 MV20D 8,10,15,18,20,25 AY012MA321 AHP18 AHP18 AY018MA321 AHP24 AY024MA321 AHP24 AY030MA321 AHP36 AY036MA321 AHP42 AY018MA321 F4FP024H06T2A AY024MA321 F4FP030H06T2A AY036MA321 F4FP042H06T2A Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
  • Page 6 246814-YTG-D-0606 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils FURNACE** UNIT MODEL CFM RANGE (MIN.-MAX.) AY012MA321 AY018MA321 1000 AY024MA321 AY030MA321 1200 1000 AY036MA321 1400 1. Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
  • Page 7 COOLING CAPACITY - Variable Speed Furnaces VARIABLE SPEED UNIT MODEL FURNACE MODEL PV8*A12 PV8*B16 PV9*A12 PV9*B12 PV8*B16 PV9*B12 PV8*A12 PV9*A12 PV8*A12 AY018MA321 PV9*A12 PV8*B16 PV9*B12 PV8*B16 PV9*B12 PV8*A12 PV9*A12 PV8*A12 PV9*A12 PV8*A12 PV9*A12 PV8*B16 PV9*B12 PV8*A12 PV9*A12 PV8*B16 PV9*B12 PV8*A12 PV8*B16 PV9*A12 AY024MA321...
  • Page 8 246814-YTG-D-0606 COOLING CAPACITY - VARIABLE SPEED FURNACES (CONTINUED) VARIABLE SPEED UNIT MODEL FURNACE MODEL PV8*B16 PV9*B12 PV8*C16 PV8*C20 PV9*C16 PV9*C20 PV8*C16 AY030MA321 PV8*C20 PV9*C16 PV9*C20 PV8*B16 PV9*B12 PV8*A12 PV9*A12 PV8*B16 PV8*C16 PV8*C20 PV9*B12 PV9*C16 PV9*C20 PV8*C16 PV8*C20 PV9*C16 PV9*C20 PV9*D20 PV8*B16 PV9*B12 PV8*C16...
  • Page 9 ACCESSORIES* Refer to Price Manual for specific model numbers. OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle to pre- vent rapid recycling of the compressor. ROOM THERMOSTATS - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation.
  • Page 10: Typical Installation

    246814-YTG-D-0606 TYPICAL INSTALLATION 48” OVERHEAD CLEARANCE 12” CLEARANCE AROUND PERIMETER NOTE:ALL OUTDOOR WIRING MUST BE WEATHERPROOF. TYPICAL FIELD WIRING ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-1-60 GND. CONTACTOR TERMINALS COIL CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF.
  • Page 11: G4Fd024H14T2A — 0

    COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AY012MA321 INDOOR COIL MODEL NO. G2FD024S17 ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 10.5 S.C. 10.7 T.C. 10.4 S.C. 10.6 T.C. 10.3 S.C. 10.3 T.C. 10.2 S.C.
  • Page 12 246814-YTG-D-0606 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AY018MA321 INDOOR COIL MODEL NO. G2FD024S17 ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 16.3 S.C. 15.4 T.C. 15.9 S.C. 15.0 T.C. 15.6 S.C. 14.7 T.C. 15.2 S.C.
  • Page 13: G4Fd036H17T2A — — — 0

    COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AY024MA321 INDOOR COIL MODEL NO. G2FD030S17 ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 21.4 S.C. 20.6 T.C. 20.9 S.C. 20.1 T.C. 20.3 S.C. 19.7 T.C. 19.7 S.C. 19.2 T.C.
  • Page 14: G4Fd036H21T2A

    246814-YTG-D-0606 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AY030MA321 INDOOR COIL MODEL NO. G2FD036S17 ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATUR ID WB (°F) T.C. 27.2 S.C. 25.6 T.C. 26.6 S.C. 25.1 T.C. 26.1 S.C. 24.5 T.C. 25.5 S.C.
  • Page 15: G4Fd048H21T2A

    COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AY036MA321 INDOOR COIL MODEL NO. G2FD042S21 ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 32.8 S.C. 32.8 T.C. 32.0 S.C. 32.0 T.C. 31.2 S.C. 30.7 T.C. 30.4 S.C. 29.3 T.C.
  • Page 16 Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2006. All rights reserved. Unitary Product Group NOTES Supersedes: 246814-YTG-C-0506 5005 York Drive 246814-YTG-D-0606 Norman 73069...