GENERaL TRouBLEShooTING
SyMPToM
6. Glass Soots
7. Flame burn blue
and lifts off burner
(ghosting)
GLaSS REPLaCEMENT
Make sure the glass panel edges do not
touch any metal parts during thermal expan-
sion.
Never operate fireplace if glass is broken.
Replace any glass that is chipped, cracked, or broken. Replacement glass assemblies MUST
be supplied by fireplace manufacturer — No substitute materials may be used.
oPTIoNaL BLowER aCCESSoRy - BLoT
wIRING dIaGRaM FoR BLowER
Attach Blower to T-Stat
Green
Green
120 VAC

Blower

Black
120 VAC
Speed Control
38
PoSSIBLE CauSE
A. Flame impingement
on logs
A. Insufficient oxygen
being supplied
BLowER
and
White
Blower Plug
Black
Black
aCTIoN
A. Install log set per the instructions
Inspect the injector and air intake area. Make sure
this area does not have any blockage from debris and
clean.
Check gas supply.
A. Ensure that the vent cap is installed properly and free
of debris. Ensure that the vent system joints are tight
and have no leaks. Ensure that no debris has been
blocking the inner air intake at the bottom back of the
combustion chamber. Ensure that the glass is properly
secure and latch.
always use gloves when handling broken
glass.
Optional Variable Speed Switch
FP2314
BLOT blower
Junction Box
TRouBLEShooTING
ON/OFF Wall Switch or
Factory Supplied
Not Supplied
120 VAC
60Hz