Chassis Description

Power failure detection system

detection of power failure
Projector provides a protection circuit to prevent the secondary failure when the power failure, fans failure or tem-
perature failure occurs on the projector. The power failure detection lines "PF_AV", "PF_AD", etc. are connected to
the main power supplies and fans. When the failure occurs, IC301<SCALER> receives an error information and then
outputs the signal "PFC_SW_EX" from pin 32. The signal "PFC_SW_EX" is supplied to power supply circuit as the
signal "PFC_SW" via IC1875 <Buffer> to control the power supply operation.

Error information table

Ic
Pin
Signal Name
345
PF_AV
138
PF_AD
245
PF_SI
67
PF_FRT
257
PF_5V_PJ
251
PF_PIC
60
PF_25V
IC301
282
PF_KS
PW392
180
PF_GAM
25
PF_9V
293
PF_S12V
154
PF_FN905&FN906
41
PF_FN907
33
PF_FN908
61
PF_FN901
62
PF_FN902
IC4801
63
PF_FN903
TE7783
64
PF_FN904
99
PF_LAN
343
FILTER_DET
IC301
388
FILTER_COUNT
PW392
281
PRESS_SENS
83
SHUTTER_POS1_PIC1
IC3401
160
SHUTTER_POS2_PIC1
connection Lines
S5V, S-5V
3.3VAD, A3.3V_AD, D3.3V_AD,
A1.8V_AD, D1.8V_AD, S2.5V_PICA
S3.3VSI, S1.2VSI
S3.3VFRT, S1..2V_FRT_INI
5V_PJ
S1.2V_PIC1, S1.2V_PIC1D,
S3.3V_PICD
25V
S1.8VSK_KS, S1.8VMPLL_KA,
S1.8VAA_KS, S3.3VAA_KS,
S3.3VAB_KS,S2.5VAB_KS,
S2.5VAA_KS, S2.5VAC_KS
1.8V_DDR, 1.0V_DI_C, 1.8V_DDR,
1.8V_DI_TX, 3.3V_DI, 3.3V_SH,
2.5V_DI_TX, 2.5V_DI_RX,
2.5V_DI, HVDD, VVDD, 15V_SHR,
15V_SHG, 15V_SHB
9V_LNS
S12V
FN905, FN906 POWER & LOCK
FN907 POWER & LOCK
FN908 POWER & LOCK
FN901 POWER & LOCK
FN902 POWER & LOCK
FN903 POWER & LOCK
FN904 POWER & LOCK
S3.3V_LAN
FILTER CONDITION DETECT
MOTOR ERROR DETECT
PRESSURE SENSOR DETECT
SHUTTER POSITION SW
-84-
error Information
Failure Area
AV,
AV
S5V, S-5V on AV board
MAIN,
AD
Main AD Power
MAIN,
SI
Main HDMI Power
MAIN,
F-FPGA
Main FPGA IC5201 Power
PJ-NET,
5V
Network Box Power
MAIN,
PIC
Main FPGA IC3401 Power
MAIN,
25V
Main 25V Power
MAIN, KEYSTONE
MAIN Keystone Power
MAIN,
GAM
Main Gamma Power
MAIN,
9V
Main 9V Power
MAIN,
S12V
Main S12V
MAIN,
FAN3
FN905&FN906 Power FAN3 & Lock
MAIN,
FAN1
FN907 Power FAN1 & Lock
MAIN,
FAN7
FN908 Power FAN7 & Lock
MAIN,
FAN6
FN901 Power FAN6 & Lock
MAIN,
FAN5
FN902 Power FAN5 & Lock
MAIN,
FAN2
FN903 Power FAN2 & Lock
MAIN,
FAN4
FN904 Power FAN4 & Lock
AV,
LAN
AV S3.3V_LAN
ERR,
FIL_DET
Filter Cartridge is not installed
ERR,
FIL_MTR
Filter Motor Error
ERR,
PRESSURE
Pressure Error
ERR,
SHUT_MTR
Shutter Operation Error