System Control

Scan

Scanning output:
You can set the image size to a VGA resolution to accommodate
older applications that require a smaller image size. When Image
VGA is set to On, the resultant image is 640x480 pixels. When
Image VGA is Off, the image is 752x480 pixels.
Scanning mode:
Manual/Serial Trigger Mode
When in manual trigger mode, the imager scans until a bar code is
read, or until the hardware trigger is released.
When in serial mode, the imager scans until a bar code has been
read or until the deactivate command is sent. In serial mode, the
imager can also be set to turn itself off after a specified time has
elapsed (see
Read
Time-Out, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the
imager's trigger if the imager is in manual trigger mode. Once the
imager has timed out, you can activate the imager by
pressing the trigger. After scanning the Read Time-Out bar code,
set the time-out duration (from 0-300,000 milliseconds) by
scanning digits from the inside back cover, then scanning Save.
Default = 0 (infinite, or no time-out).