Argox AS8520 Manual
Hide thumbs Also See for AS8520:

Advertisement

NOTICE:
This equipment has been tested and complied with
This device complies with Part 15 of the FCC Rules.
Operation shall be subject to the following two
conditions:
(1) This device may not cause harmful interface, and
(2) This device must accept any interface received,
including interface that may cause undesirable
operation.
the limits for a Class a digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to
provide a reasonable protection against harmful
interface when the equipment is operated under a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interface to
radio communications. Operation of this equipment in
a residential area is likely to cause harmful interface in
which case the user will be required to correct the
interface at his own expenses.
Note: All brands and trademarks shall belong to their
respective owner.
Note: Specification is subject to changes without
notice.
i

Advertisement

Table of Contents
loading

Summary of Contents for Argox AS8520

  • Page 1 NOTICE: This equipment has been tested and complied with This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including interface that may cause undesirable operation.
  • Page 2 Using the Cordless Scanner The Scanner can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code (see “How to Scan”...
  • Page 3 AS-8520 Scanner EN 300 328 BT RF Power EIRP 9.98 dbm AS-8520 Cradle EN 300 328 BT RF Power EIRP 7.48 dbm 警告: 電池若未妥善處理, 可能會導致爆炸。 請勿拆卸電池, 或用火銷毀電池。 請將電池放置於兒童拿不 到的地方。 請使用專用充電器充電, 並請依照當地政府或法 律規定妥善處理廢棄電池。 CAUTION: EXPLOSION HAZARD Do not disassemble, short circuit, heat the battery or dispose of in fire.
  • Page 4: Table Of Contents

    CONTENTS Chapter 1 Introduction Installation…………………………………………… How To Scan………………………………………… Troubleshooting……………………………………… Wireless Connection………………………………… Battery Charging…………………………………… Wireless Features…………………………………… Auto Update……………………………………… Data Collection Mode......... Deep Sleep Mode……………………………… Wireless Connectivity…………………………… Inquiry Beep control…………………………… Cradle Beep Loudness Control………………… Additional Features……………………………… Default Setting.……………………………………… Specification………………………………………… Indications of Cordless Scanner…………………… Imager……………………………………………...
  • Page 5 UPCE ………………………………………………… EAN-13.……………………………………………… EAN-8 ………………………………………………… Code 39 ……………………………………………… Interleaved 2 of 5 …………………………………… Industrial 2 of 5 ……………………………………… Matrix 2 of 5 Eur …………………………………… Codabar ……………………………………………… GS1-128 ………………………………… Code-128 Code-93 ……………………………………………… Code-11.……………………………………………… MSI/Plessey.………………………………………… UK/Plessey.………………………………………… Telepen.……………………………………………… Standard 2 of 5 ……………………………………… 101 China Post ……………………………………………...
  • Page 6 Parameter Setting List.……………………………… 135...
  • Page 7: Installation

    Installation The Cordless Scanner is easy to install and use. Please see the following figure showing the steps to perform the installation. * Note: Turn off the host computer before installation. Connect the interface (I/F) cable to the cradle. Connect the power cord to the cradle. Route the I/F cable and power cord through the notch.
  • Page 8 imager should emit a beep indicating that the barcode has been scanned and transmitted to the cradle successfully. Connecting Scanner to PC via Bluetooth USB Dongle The cordless scanner is allowed to connect PC via Bluetooth USB dongle. 1. Scan the following barcodes to set scanner to Bluetooth connection mode, with PIN code as 0000 or refer to the manual page 22 to set any four-to-six character PIN...
  • Page 9 Within the prompt, click ” Add”: 3. Check the option, “My device is set up and ready to be found” and click Next:...
  • Page 10 4. Select “AS8520…” among the Bluetooth devices found; click “Next”: 5. Select “Don’t use a passkey” and click “Next”. The Bluetooth connection will start to install the Bluetooth device for the cordless scanner:...
  • Page 11 6. As it prompts, “Completing the Bluetooth Device Wizard”, find which COM ports is assigned. The following example lists COM23 as the Outgoing port, and COM24 as Incoming port; your actual COM ports will depend on what’s assigned on your PC:...
  • Page 12 7. Open HyperTerminal. Set COM1’s Baud Rate as 9600 to communicate with the cordless scanner (whose default baud rate is 9600):...
  • Page 13 8. Select COM23 (depending on your Outgoing COM port) to connect: 9. Click on “Dial”...
  • Page 14 10. The system will show a message on Taskbar asking to click on the Bluetooth sign on taskbar. After clicking on it, the wizard will prompt as below; enter 0000 (cordless scanner’s default PIN code) within the Passkey field; click “Next”. Now the installation and setups have been completed, you may start to scan barcodes to transmit data to HyperTerminal on PC.
  • Page 15 Go to “General” – “Bluetooth” and turn the Bluetooth On. Then the Bluetooth device searching will start. Your Apple device will find Argox Cordless Scanner “AS8520 XXXXXXXXX” under the status of “Not Paired”. Click the found device and you will hear three beeps after certain connecting time.
  • Page 16 Note: Apple iOS devices will allow only one input device working at the same time. So when you connect an Argox Cordless Scanner with your Apple device, the Apple Virtual Keyboard will be invalid automatically. To have the Apple Virtual Keyboard be available again, your will need to scan the barcode below.
  • Page 17 Note: Android system will allow both the connected input device and the Android Virtual Keyboard working at the same time. So when you connect an Argox Cordless Scanner with your Android device, the Android Virtual Keyboard will be still available for your input.
  • Page 19: How To Scan

    How To Scan The imager must be pointed at slight angle to the barcode so that the light reflected off the barcode can be seen by the imager. Do not hold the imager perpendicular to the barcode. The scan line must cross the entire barcode. The imager can not read the barcode data without seeing the entire barcode.
  • Page 20: Troubleshooting

    Troubleshooting If the imager can not operate properly, the following checks should be performed: The cradle uses an external power supply and the external power supply has failed, the imager will not operate. Change the power supply with a known good power supply and reset the imager.
  • Page 21 Verify the interface cable is securely connected to the cradle. Check that the barcodes are of sufficient quality to be recognized by the imager. Wrinkled, smudged, or torn labels will cause the imager to not read at all. Scan a known good label to check the imager’s read operation.
  • Page 22: Wireless Connection

    Wireless Connection Linking the imager with the cradle Follow these instructions to link the two devices: Connect power to the cradle. The radio LED (marked with a light symbol) will blink amber and the cradle will beep. To ensure the cradle is unlinked from any other imager, check if the cradle send inquiry beep or not (see Inquiry Beep Control in page 23 Read the link label on the bottom of the cradle with the...
  • Page 23: Battery Charging

    Unlinking There are three ways to unlink an imager from a cradle: Force imager to disconnect and sleep Scan the “Force imager to disconnect and sleep” barcode – Reading the unlink barcode above while the imager is in range of the cradle will break the link between the two devices and allow another imager to link to the cradle.
  • Page 24 The imager contains a 1000mAh Lithium-Ion rechargeable battery. A full charged battery will provide up to 55,000 scans over a 15 hours period. Actual charge life on the imager will depend on the configuration of how the imager is configured via the programmable feature in this manual;...
  • Page 25 How to Change the Battery In case the contained battery inside the imager needs to be replaced, please follow the procedures below: 1. Loosen the screw at the bottom of the imager. 2. Take off the battery container out of the imager. 3.
  • Page 26 6. Place the new battery into the battery container. 7. Connect the battery cable connector to the handle board. 8. Put the battery container back to the imager handle. 9. Fasten the screw to the imager. Note: DO NOT touch the PCBA inside the imager when replacing the battery.
  • Page 27: Wireless Features

    Wireless Features The Cordless Scanner includes an imager and a cradle. When the imager and cradle are linked together, the imager will read and decode barcodes and transmit them via a Wireless radio to the cradle. The cradle will then transmit the barcode data to the host computer over the host cable.
  • Page 28: Auto Update

    Auto Update When this feature is enabled, an imager and its linked cradle can automatically ensure they stay in sync with regard to firmware and/or configuration. This is accomplished by the linked imager and cradle comparing firmware version number and configuration file check sum. If either is different, the cradle will automatically update the imager with its firmware/configuration.
  • Page 29: Data Collection Mode

     Enable firmware auto update only – Allows only firmware updating.  Disable auto update – No automatic updates will be performed. Data Collection Mode You can decide whether your scanner stores data in its storage when it lost Bluetooth connection. The storage size is 1 KB.
  • Page 30: Deep Sleep Mode

    Deep Sleep Mode The WIRELESS imager can be placed into Deep Sleep Mode after this programmed duration (since the units’ last scanning activity). Press its trigger to wake the imager form this mode.  Disable Deep Sleep Mode (Default)  Duration 10 minutes - Force imager into deep sleep mode if there is no barcode read in 10 minutes.
  • Page 31: Wireless Connectivity

    Wireless Connectivity The cordless scanner can be linked to any Bluetooth (BT) enabled device which can accept such a connection with other devices. To implement this feature, user should set the imager to “Cradle/Dongle connection auto detection” first. And then set the PIN code to 0000 assigned to the target Bluetooth device.
  • Page 32 Wireless Connectivity (continued) User is also allowed to set any four- to six-character PIN code assigned to the target Bluetooth device using the setting procedures below: STATE CODE Cradle/Dongle connection auto detection Program Begin PIN setting PIN no. (Set 4~6 character) End PIN setting...
  • Page 33: Inquiry Beep Control

    Inquiry Beep Control When the cradle is not linked to an imager, the Radio LED will blink amber and the cradle will beep. This beep can be disabled or reconfigured to sound for different durations by using the following programming barcodes. ...
  • Page 34  Inquiry beep every 50 seconds  Inquiry beep every 60 seconds  Inquiry beep every 70 seconds...
  • Page 35: Cradle Beep Loudness Control

    Cradle Beep Loudness Control The beep loudness of cradle can be defined with the following levels.  Cradle beep off  Level 1  Level 2  Level 3 (Default)  Level 4  Level 5...
  • Page 36  Level 6  Level 7...
  • Page 37: Additional Features

    Additional Features Here list three additional features of the cordless scanner wireless imager for the convenience of use to users.  Download firmware from the cradle  Download configuration parameters from the cradle  Force cradle to reset the configuration – This feature will also force imager to reset the configuration to factory default.
  • Page 38: Default Setting

    Default setting For each barcode shown as below: Checksum Checksum Read Code Code Type Verification Transmission Enable Enable Enable UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 V two digits Code-93 &...
  • Page 39: Specification

    Specification Cordless Scanner Specification Operational Light Source 630 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field Up to 600mm (CODE 39, PSC=90%, 20mils) Scanning Width 160mm Scan Speed 450 scans/sec 0.1mm (4mils) Resolution Code39,PCS=90% Print Contrast 25% or more...
  • Page 40 Width-head 78 mm Depth-handle 56 mm Depth-head 35 mm Cradle 210 (L) x 109 (W) x 51 (H) mm Weight Less than 250g (with a battery) Case material ABS (over molded at contact points) Cushion material Double injection Cradle interface RS232, Keyboard wedge, USB Electrical Input Voltage...
  • Page 41 Current – Standby 32 mA (Imager) Current – Sleep 2 mA (Imager) Light Level Up to 70000 Lux Shock (Imager) 1.5m drop onto concrete Shock (Cradle) 90cm drop onto concrete Contaminants Seals to resist airborne particulate contaminants (IP42) Ventilation None required Programming Programming Manual (Reading special barcode),...
  • Page 42: Indications Of Cordless Scanner

    Indications of Cordless Scanner Imager: Green Orange Status Red LED Beeper Link Blink A special established once beep Hardware Flash fail Program Flash download Program checksum Flash fail High freq. Data Beep for transmitting 300msec Data trans. ON for Error beep Fail 300msec Data trans.
  • Page 43: Cradle

    Cradle: Green Orange Status Beeper Beeps Inquiry Blink once a second Connecting Blink Link established Hardware fail Flash Data receiving ON for from the 0.5sec status scanner Barcode data Good proof or beep transmitted Data send to Error the host Fail beep Program Flash...
  • Page 44: Programming The Cordless Scanner

    Programming the Cordless Scanner To program the cordless scanner, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.
  • Page 45 Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge Interface RS-232 selection Wand emulation Keyboard/RS-232 Auto detection Reserved Exit Option Barcode Back Fold Out Exit Barcode Finish barcode...
  • Page 46: Interface

    Interface Selection This cradle comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, and USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface.
  • Page 47: Keyboard Wedge

    Keyboard wedge As a keyboard interface, the cradle supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer.
  • Page 48 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard”...
  • Page 49 Belgium Keyboard layout Danish France Germany Italian Portuguese Spanish Swedish Switzerland Latin American Japanese 00-08 0 : high clock rate Keyboard speed 8 : low clock rate Disable Enable Function key Alphabetic key Numeric keypad Alpha/Numeric key (Num lock state only) Alt+Keypad Exit...
  • Page 50 Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, imager can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on.
  • Page 51 Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” Caps lock”OFF” Caps lock Disable Enable Power-on simulation 00-99 (msec) 00-99 Inter-character delay 00-99 (10 msec) 00-99 Block transmission delay Exit RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 11...
  • Page 52 Xoff: Transmit Off (ASCII Code13 Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the cradle wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication.
  • Page 53 Entry None RTS/CTS Flow control Xon/Xoff ACK/NAK RTS/CTS bracket mode 00-99 (msec) 00-99 Inter-character delay 00-99 (10 msec) 00-99 Block transmission delay 00-99 (100 msec) 00-99 Response delay Exit Program...
  • Page 54 Option Bar Code Option Alphanumeric Entry 300 BPS 600 BPS Baud rate 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS None Parity Even 8 bits 7 bits Data bit One bit Two bits Stop bit Exit...
  • Page 55: Pin Assignments

    Pin Assignments 10-pin AS Series 10-pin RJ-45 Connector RS-232 Keyboard CLK / PC DATA / PC DATA / KB CLK / KB...
  • Page 56 Keyboard Wedge PS/2 Connector (To Host Side): Mini-DIN 6P Male Mini-DIN 6P Female DATA / PC DATA / KB VCC (+5V) CLK / PC CLK / KB Mini-DIN 6P Female Connector Mini-DIN 6P Male Connector Femal RS-232 DB-9F Connector (To Host Side): Definition Conne ctor...
  • Page 57: System Control

    Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of imager stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning.
  • Page 58 Program Option Bar Code Option Alphanumeric Entry Good-read off Momentary Scanning mode Alternate Timeout off Continue Test only Auto-sensing 01-99 (second) 00-99 Stand-by duration 01-99 (10 msec) 01-99 Double read timeout 00-09 00-09 (00: no double Double confirm confirm) 00-64 00-64 (verifications) Supplement Check...
  • Page 59 Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code length or more than max. code length will not be read. In popular, you can set the same value for both min.
  • Page 60 Program Option Bar Code Option Alphanumeric Entry 00-99 00-99 Global min. code length 00-99 00-99 Global max. code length Disable Enable Inverted image scan Exit...
  • Page 61: Indication

    Indication Power on alert: After power-on the cradle it will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the imager will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the imager will beep buzzer to indicate a good barcode reading, and its Beep loudness, Beep tone freq.
  • Page 62 Program Option Bar Code Option Alphanumeric Entry Disable Enable Power on alert Disable Enable LED indication Disable Enable Beeper indication 00-07 00-07 (00 - off) Beep loudness 00-99 (100Hz) 00-99 Beep tone freq. 00-99 (10 msec) 00-99 Beep tone duration Exit...
  • Page 63: Code Option

    UPCA Format Leading Data Digits Check Zero (11 Digits) Digit Read: Enable or disable the read function. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero.
  • Page 64 Option Bar Code Option Alphanumeric Entry Disable Enable Read Disable Enable Check-sum transmission 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < A > Code ID setting Exit...
  • Page 65 UPCA Insertion group number selection: The imager offers max. two insertion groups for one symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. The function is to insert specific characters as a group into transmitted data of selected symbologies.
  • Page 66 Program Option Bar Code Option Alphanumeric Entry 00-44 00-44 Insert group number selection None 2 digits Supplement digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 None Truncate leading Truncation/ zero Expansion Expand to EAN13 Exit...
  • Page 67: Upce

    UPCE Read: Format Leading Data Digits (6 Check Zero Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Program Option Bar Code Option Alphanumeric...
  • Page 68 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < E > Code ID setting Exit...
  • Page 69 UPCE Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. Supplement digits: Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (6 Digits) Digit UCC/EAN Expansion: The expansion function is used only for UPCE and EAN-8 code reading.
  • Page 70 None 2 digits Supplement digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 None Truncate leading Truncation/Expansion zero Expand to EAN13 Expand to UPCA Disable Enable Expansion Disable Enable UPCE-1 Exit...
  • Page 71: Ean-13

    EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Truncate leading zero: Refer to Truncation / Expansion of UPCA. Program Option Bar Code Option Alphanumeric Entry...
  • Page 72 0-15 00-15 Truncate ending Exit...
  • Page 73 EAN-13 Code ID setting: Refer to page 55 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (12 Digits) Digits UCC / EAN ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two...
  • Page 74 None 2 digits Supplement digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 Disable Enable ISBN/ISSN conversion 00-ffH ASCII 00-ffH code < I > ISBN ID setting Exit...
  • Page 75 EAN-8 Read: Format Data Digits Check (7 Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA.
  • Page 76 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH, 00-ffH code < FF > Code ID setting 00-44 00-44 Insert group number selection Exit...
  • Page 77 EAN-8 Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (7 Digits) Digits UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE. Program Option Bar Code Option Alphanumeric Entry None 2 digits...
  • Page 78 Disable Enable Expansion Exit...
  • Page 79 Code 39 Read: Format Start Data Digits Checksum “★” “★” ( Variable) (Optional) Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted.
  • Page 80 Disable Enable Check-sum verification Disable Enable Check-sum transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < > Code ID setting Exit...
  • Page 81: Code 39

    Code 39 Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z).
  • Page 82 Standard Full ASCII Format Disable Enable Append Disable Enable Start/end transmission Exit...
  • Page 83: Interleaved 2 Of 5

    Interleaved 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 84 Disable Enable Check-sum transmission 00-64 00-64 Max. code leading 00-64 00-64 Min. code leading 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group number selection Exit...
  • Page 85: Industrial 2 Of 5

    Industrial 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA.
  • Page 86 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group number selection Exit...
  • Page 87: Matrix 2 Of 5 Eur

    Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min.
  • Page 88 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < B > Code ID setting 00-44 00- 44 Insert group number selection Exit...
  • Page 89: Codabar

    Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 90: Code-93

    Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < % > Code ID setting Codabar Exit Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA.
  • Page 91: Code-128 / Gs1-128

    Start/End Transmission: Refer to Start/End Transmission of Code 39. Program Option Bar Code Option Alphanumeric Entry 00-44 00-44 Insert group selection ABCD/ABCD abcd/abcd Start/End type ABCD/TN*E Abcd/tn*e Disable Enable Start/End transmission Code-128 Exit Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits.
  • Page 92 be transmitted. Program Option Bar Code Option Alphanumeric Entry Disable Enable Read Disable Enable Checksum Verification Disable Enable Checksum Transmission Exit...
  • Page 93 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character.
  • Page 94 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < # > Code ID setting 00-44 00-44 Insert group number selection Standard UCC/EAN-128 Format Disable/Enable Enable/Enable Append / FNC4 control Disable/Ignore Enable/Ignore Exit...
  • Page 95 Code-128 ISBT enable: This feature is commonly used in a blood bank for identification. ISBT concatenation timeout: This feature is to setup the timeout duration of ISBT concatenation. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you your can reassign second or after a FNC1 for usage.
  • Page 96 Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry...
  • Page 97 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. Program Option Bar Code Option...
  • Page 98 00-ffH ASCII 00-ffH code < & > Code ID setting 00-44 00-44 Insert group number selection Exit...
  • Page 99: Code-11

    Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min.
  • Page 100 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < O > Code ID setting 00-44 00-44 Insert group number selection Exit...
  • Page 101: Msi/Plessey

    MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits.
  • Page 102 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < @ > Code ID setting 00-44 00-44 Insert group number selection Exit...
  • Page 103: Uk/Plessey

    UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 104 Disable Enable Checksum Transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < @ > Code ID setting 00-44 00-44 Insert group number selection Exit...
  • Page 105: Telepen

    Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 106 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < S > Code ID setting 00-44 00-44 Insert group number selection Numeric only Full ASCII only Format Exit...
  • Page 107: Standard 2 Of 5

    Standard 2 of 5 Read: Format Data Digits Checksum1 (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 108 Disable Enable Check-sum transmission 00-64 00-64 Max. code length 00-64 00-64 Min. code length 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < i > Code ID setting 00-44 00-44 Insert group number selection Exit...
  • Page 109: China Post

    China Post Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA.
  • Page 110: Italian Pharmacode (Code 32)

    0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < t > Code ID setting 00-44 01-44 Insert group number selection Exit Italian Pharmacode (Code 32) Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of...
  • Page 111 Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. Leading “A”: If this function is enabled, each prefix of data shall be A.
  • Page 112: Code-16K

    Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 01-ffH code < p > Code ID setting 00-44 00-44 Insert group number selection Disable Enable Leading “A” Code-16K Exit Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA.
  • Page 113 Option Bar Code Option Alphanumeric Entry Disable Enable Read 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < > Code ID setting...
  • Page 114 00-44 00-ffH 00-44 Insert group number selection Exit...
  • Page 115: Pdf-417

    PDF-417 Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA.
  • Page 116 Program Option Bar Code Option Alphanumeric Entry Disable Enable Read 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < P >* Code ID setting 00-44 00-44 Insert group number selection Disable Enable Escape sequence transmit Exit...
  • Page 117: Ean Ucc Composite

    EAN UCC Composite For the coupon extended code application. Coupon extended code is a supplementary barcode that is printed to the right of the UPC/EAN in UCC/EAN-128 symbology. Program Option Bar Code Option Alphanumeric Entry Disable Enable Read 0-15 00-15 Truncate leading 0-15 00-15...
  • Page 118 Insert group number selection Disable Enable UCC / EAN128 emulation Exit...
  • Page 119: Rss-14

    DataBar (RSS-14) Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission, Code ID transmission must be set as AIM ID enable.
  • Page 120 0-15 00-15 Truncate leading 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < R4 > Code ID setting 00-44 00-44 Insert group number selection Disable Enable UCC/EAN128 emulation Exit...
  • Page 121: Rss-Limited

    DataBar (RSS-Limited) Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
  • Page 122 00-ffH ASCII 00-ffH code < RL > Code ID setting 00-44 00-44 Insert group number selection Disable Enable UCC/EAN128 emulation Exit...
  • Page 123: Rss-Expanded

    DataBar (RSS-Expanded) Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
  • Page 124 0-15 00-15 Truncate ending 00-ffH ASCII 00-ffH code < RX > Code ID setting 00-44 00-44 Insert group number selection Disable Enable UCC/EAN128 emulation Exit...
  • Page 125: Micro-Pdf

    Micro-PDF Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 55 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable Enable Read...
  • Page 126 00-44 00-44 Insert group number selection None GLI protocol Escape sequence ECI protocol transmit Exit...
  • Page 127: String Format

    String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies. Up to 22 ASCII characters can be defined as Prefix or Suffix. Format of barcode data transmission: Code Barcode...
  • Page 128 Program .Option Bar Code Option Alphanumeric Entry None 1-22 characters 00-ffH ASCII Prefix characters code setting None 1-22 characters 00-ffH ASCII Suffix characters code setting Exit...
  • Page 129: String Setting / Transmission (Preamble/Postamble)

    String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data automatically for all symbologies. However, the transmission will not activate unless Preamble / Postamble transmission is enabled. Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted.
  • Page 130 Program Option Bar Code Option Alphanumeric Entry “ ” 1-22 characters PREAMBLE 00-ffH ASCII Preamble characters code setting Disable Enable Preamble transmission “ ” 1-22 characters POSTAMBLE 00-ffH ASCII Postamble code characters setting Disable Enable Postamble transmission Exit...
  • Page 131: String Setting / Transmission (Insert Group Characters)

    String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The imager supports inserting two groups with each group 22 characters into transmitted data of selected symbologies. The two groups can be inserted into scanned data of the selected symbologies or positioned at leading / ending of data.
  • Page 132 5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. Insert data group 1-4 position. Please refer to the specific barcode that you want to use. Insert data group 1-4 position: The imager offers 4 positions to insert among the symbol. The position default value is “00”...
  • Page 133 Option Bar Code Option Alphanumeric Entry “GROUP1” 1-22 characters 00-ffH ASCII Insert G1 characters code setting “GROUP2” 1-22 characters 00-ffH ASCII Insert G2 characters code setting “GROUP3” 1-22 characters 00-ffH ASCII Insert G3 characters code setting “GROUP4” 1-22 characters 00-ffH ASCII Insert G4 characters code setting...
  • Page 134 00-64 00-64 (00: no insertion) Insert data group 2 position 00-64 00-64 (00: no insertion) Insert data group 3 position 00-64 00-64 (00: no insertion) Insert data group 4 position Exit...
  • Page 135: String Setting / Transmission (Others)

    String setting / Transmission (Others) Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted. Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected.
  • Page 136 Before code data After code data Code ID position Disable Proprietary ID Code ID AIM ID transmission Disable Enable Code length transmission Disable Enable Code name transmission Disable Upper case Case conversion Lower case (For barcode data only) Exit...
  • Page 137: Appendix

    Test Chart (Bar code samples marked with symbol “*” are enabled initially.) CODABAR-PARA CODE-11 PARA CODE-128 PARA * CODE-39 PARA * CODE-93 PARA EAN-13 PARA *...
  • Page 138 PDF-417 * STANDRAD-25 PARA CODE-16K 87549 EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA *...
  • Page 139 INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA Micro-PDF *...
  • Page 140: Ascii Code Table

    ASCII Code Table Note: For keyboard wedge only. Null Down Left Right PgUp PgDn Home Enter Insert Ctrl+ Delete Alt+ “ & ‘ ★ ﹛ , < \ ︱ ﹜ > 〜...
  • Page 141 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current barcode reading configuration of your cordless scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code. System parameter setting list If you wish to display the current system configuration of your cordless scanner over the host terminal/computer, scan the System parameter setting list bar code.
  • Page 142 Query present cradle firmware version Program Firmware version list If you wish to display the cradle and imager firmware versions, scan the “Firmware version list” barcode. Exit Reset cradle to factory default settings WARNING: Default value initialization If you wish to return the cordless scanner to all the factory default settings, scan the above barcode will perform the feature.
  • Page 143 Finish...

Table of Contents