Specifications; Inspection & Service - Rinnai RER-55AS Operation & Installation Manual

Natural gas & ulpg gas rice cooker
Table of Contents

Advertisement

Gas Input Main burner
Main burner Injector Ø
Gas Input - Pilot
Pilot Injector Ø
Dimensions
Regulator
Gas Control Valve
Gas Control Knobs
Flame Failure Device (FFD)
Thermal Control - Burner protection
Inlet pressure
Burner pressure
Clearances to Combustibles
Gas Connection
Weight - (Net)
Base Material
Heat Shroud
Pot Material
Lid Material
Cooked Rice Capacity
Rinnai Australia Pty Ltd. Reserves the right to make modification and change specifications without notice.
Rinnai recommend that this appliance be inspected and serviced by an authorised person annually.
Rinnai Australia

SPECIFICATIONS

RER - 55AS(NG)
INSPECTION AND SERVICE
(Natural Gas)
35 MJ/hr
2.80 mm
0.3 MJ/hr
0.25 mm
Height: 455 mm
Width: 610 mm
Depth: 476 mm
Internal
Rinnai Japan - # DRR37-213-10 (ULPG)
Rinnai Japan - # DRR37-213-9 (NG)
ABS moulded plastic
Thermo-electric FFD
Mechanical Thermal cut out
1.13 kPa
0.85 kPa
Sides and Rear: minimum 150 mm
Top: minimum 600 mm
1/2" BSP Female
16 kg
Powder Coated Steel
Vitreous Enamel Coated Steel
Cast Aluminium
Stainless Steel
10 litres
7
Rice Cooker Operation & Installation Manual
RER - 55AS(ULPG)
(Universal LPG)
35 MJ/hr
1.67 mm
0.4 MJ/hr
0.21 mm
2.75 kPa
2.65 kPa

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents