Simple Connection Of The Mks-8080/8082 Aux Bus Remote Panel; Procedure For Simple Connection - Sony MVS-8000 User Manual

With ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

Simple Connection of the MKS-8080/8082
AUX Bus Remote Panel

Procedure for Simple Connection

To carry out simple connection of the MKS-8080/8082 AUX Bus Remote
Panel, use the following procedure.
For settings on the MKS-8080/8082, refer to the section "Making the Setting
With Buttons (Setup Function)" in the Operation Manual for the MKS-8080/
8082.
1
Carry out initialization of the MKS-8080/8082 settings.
This can be done on the MKS-8080/8082 separately.
2
Set the MKS-8080/8082 station number in the range 2 to 17.
This can be done on the MKS-8080/8082 separately.
3
Set the S-Bus data link primary station to the CCP-8000 Center Control
Panel.
• For MKS-8010, set the STATION ID switches S903 on the front of the
CA-45 board in the SCU SLOT 1 to 001 (switch 1 only to the OPEN
position).
• For MKS-8010A, set the STATION ID switches S108 on the front of the
FP-141 board in the SCU SLOT 1 to 001 (switch 1 only to the OPEN
position).
4
In the Engineering Setup >System >Initialize menu, select PNL, and carry
out a reset.
This carries out a restart, and when the restart is completed connection to
the MKS-8080/8082 is possible.
5
In the Engineering Setup >Router/Tally > Router menu, set the position of
the MVS-8000 system in S-Bus space.
Select the setting from SWR1 and SWR2, and set each of Source,
Destination, and Level to 1.