Blower Data - Carrier 50YDV Installation, Operation And Maintenance Instructions

Residential horizontal & vertical packaged geothermal heat pumps
Table of Contents

Advertisement

R e s i d e n t i a l P a c k a g e d U n i t s - 6 0 H z P u r o n
R e v. : 4 J a n . , 2 0 1 2
GT-PX (50YD) Series ECM Blower Performance Data
Airfl ow in CFM with wet coil and clean air fi lter
Max
Model
ESP
Motor
(in. wg)
0.50
0.50
026
0.50
0.50
0.50
0.50
038
0.50
0.50
0.75
0.75
049
0.75
0.75
0.75
0.75
064
0.75
0.75
0.75
0.75
072
0.75
0.75
Factory shipped on Tap Setting 2
During Auxiliary operation (residential units only) the CFM will run at the higher if the heating (delay jumper) or AUX settings
Airfl ow is controlled within +/- 5% up to Max ESP shown with wet coil and standard 1" fi berglass fi lter
Do not select Dehumidifi cation mode if HP CFM is on setting 1
All units AHRI/ISO/ASHRAE 13256-1 rated HP (Cooling) Delay (Heating) CFM Setting 3
Note: See the ECM Blower Control section for information on setting taps.
26
Fan
Cooling Mode
Tap
Setting
Stg 1
Stg 2
(hp)
1/2
4
810
950
1/2
3
725
850
1/2
2
620
730
1/2
1
520
610
1/2
4
1120
1400
1/2
3
1000
1250
1/2
2
860
1080
1/2
1
730
900
1
4
1460
1730
1
3
1300
1550
1
2
1120
1330
1
1
940
1120
1
4
1670
2050
1
3
1500
1825
1
2
1280
1580
1
1
1080
1320
1
4
1620
2190
1
3
1500
1950
1
2
1400
1830
1
1
1320
1700
®
Dehumid Mode
Fan
Stg 1
Stg 2
Fan
475
630
740
475
425
560
660
425
370
490
570
370
300
700
870
1090
700
630
780
980
630
540
670
840
540
450
870
1140
1350
870
780
1020
1210
780
670
870
1040
670
560
1020
1300
1600
1020
920
1160
1430
920
790
1000
1230
790
660
1050
1270
1650
1050
980
1170
1520
980
910
1100
1420
910
850
Residential
Units Only
Heating Mode
AUX
CFM
Stg 1
Stg 2
Fan
920
1060
475
4
825
950
425
3
710
820
370
2
600
690
300
1
1120
1400
700
4
1000
1250
630
3
860
1080
540
2
730
900
450
1
1560
1850
870
4
1400
1650
780
3
1200
1430
670
2
1010
1200
560
1
1860
2280
1020
4
1650
2050
920
3
1430
1750
790
2
1200
1470
660
1
1690
2230
1050
4
1600
2100
980
3
1400
1850
910
2
1240
1620
850
1
Aux/
Emerg
Mode
1060
950
820
690
1400
1350
1350
1350
1850
1660
1430
1350
2280
2040
1750
1470
2230
2100
1870
1670

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50yeh50yed50ydh50ydd50yevGt-px series ... Show all