Remote Readout (According To Model) - Konica Minolta bizhub 43 Service Manual

Table of Contents

Advertisement

6.

REMOTE READOUT (ACCORDING TO MODEL)

Caution -
Before and after each intervention on a machine equipped with the Remote Readout
option, perform a manual transmission of the Remote Readout parameters to the Server
center, if the state of the machine allows it.
All MFP are equipped with the Remote Readout option (locked).
The option is unlocked by the installer or maintenance technician during the initial installation or during
the intervention following the subscription of the contract.
When intervening on these machines, it is very important to proceed with care, because the remote
readout parameters are verified by the processing center in order to detect any anomalies: , such as
moving the machine, withdrawal, unintentional modification of the parameters, attempted fraud.
At each automatic transmission, the Remote Readout parameters are transmitted in the night to the
Server center. A report of the transmission of these parameters is printed.
6.1
E
NABLING THE REMOTE READOUT
To enable the remote readout:
• Select Hidden settings (MENU * 9559),
• Choise Remote reading,
• Enter the parameters of remote reading:
- Service center : Enter the service center number.
- Emission :
- Without : Remote readout is not activated
- Fax :
Remote readout is activated.
Remote reading will be sent by fax.
- File :
Remote readout is activate.
Remote reading will be sent by file (transparent mode)
- Define the parameters for remote readout.
The essential parameters that trigger a remote readout are the interval in days and the page thresholds.
Once the parameters have been entered, they can be consulted by means of the K
* 9559 and printed by means of the K
button .
6.2
T
RIGGER CRITERIA
The remote readout can be triggered by two types of criteria: day or threshold.
• The "day" criterion is based on the "interval in days" parameter entered in the remote readout
menu accessed by means of the K
..."
ORDER
BUTTON
the end of which a remote readout is transmitted: If the parameter has been set to 30, a remote
readout will be transmitted every 30 days. This parameter cannot exceed 365 days. A
transmission using the day criterion allows the server center to regularly monitor its installed
base of machines and to detect any anomalies that may occur. The remote readout using the day
criterion can be disabled by entering an interval of zero.
- 39 -
EY SEQUENCE
EY SEQUENCE
, "D
"
AYS INTERVAL
BUTTON
MENU * 1881 PRINT button, SETTINGS
MENU * 9559,"C
. This parameter represents the inter-val at
IG 3000361032 - 01
MENU
EY SEQUENCE
ONSUMABLES AUTOMATIC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents