Set Water Hardness Number; Set Recharge (Regeneration) Time - Kenmore ULTRASOFT 250 625.38826 Owner's Manual

Kenmore water system user manual
Table of Contents

Advertisement

C. PROGRAM
THE TIMER
_SET
WATER HARDNESS
NUMBER
eE!
SET RECHARGE
(REGENERATION)
TIME
Press
the SELECT button
once to display
25
(flashing)
and HARDNESS.
The grains
per gallon
(gpg) hard-
ness
of your
water
supply
is on
your
water
analysis
report.
Be
sure to enter water
test results
on
page
A, for future
reference.
If your
water
supply
contains
iron, compensate
for
it by adding
to the water
hardness
number.
For ex-
ample, assume your water is 20 gpg hard and contains
2
ppm iron. Add 5 to the hardness
number for each I ppm
of iron. In this example, you would use 30for
your hard-
ness number.
20 gpg hardness
2 ppm
iron x 5 = 10
+l.___fl0
(times)
30 HARDNESS
NUMBER
• Press
the UP / DOWN
buttons
to set your
water
hardness
number
in the display.
The DOWN
button
moves
the display
to 1. The UP button
moves
the
display
to the highest
setting
(see maximum
setting
for your
model
in the specifications).
Note:
Each press
of the UP / DOWN
button
changes
the
display
by I between
I and 25. Between
25 and the
highest
number,
the
display
changes
5
at
a
time...
25, 30, 35, etc. Holding
the UP or DOWN
but-
ton in changes
the display
twice
each second.
Press
the SELECT
button
to display
2:00 AM
(flashing)
and RECHARGE
TIME.
At the 2:00 AM
recharge
time
setting,
the softener
begins
re-
generation
(see pages
2-4
and
2-5) at 2:00 AM. This is a good
time in most households
because
water
is not being
used
(see Automatic
Bypass,
page 2-6).
If a differ-
ent recharge
time setting
would
be better
for your
household,
do the following.
• Press
the UP / DOWN
buttons
to set the desired
recharge
starting
hour. Be sure to observe
the AM-
PM as you did when
setting
the present
time of day.
Note:
Each press
of the UP / DOWN
buttons
changes
the
display
one hour.
Holding
the buttons
in changes
the display
twice
each second.
Press
the SELECT
button
once
again,
to com-
plete
initial
programming,
and
RECHARGE
TO-
NIGHT
shows
in the display.
BIB,
w,
R
IF YOU NEED HELP
PROGRAMMING
THE TIMER,
CALL TOLL FREE,
NUMBER
1 - 800 - 426 - 9345.
SEE PAGES 2-1, 2-2 AND 2-3 FOR OTHER
FACE PLATE
TIMER
FEATURES.
1-4
Problems,
Questions?
Call
1-800-426-9345
Kenmore
Water
Line

Hide quick links:

Advertisement

Table of Contents
loading