SECTION3
CARE OF YOUR WATER SOFTENER
D. CHECKLIST
... TO HELP YOU SAVE MONEY
If your
water
softener
fails to work, make
the following
easy checks.
Often, you will find what's
wrong
your-
self and you won't
have
to call and wait for service.
If you do not find anything
wrong,
while
making
the
checks,
and your
softener
still does not work,
call your
Sears
Service
Department.
Note:
1. Also read
ERROR
CODE,
page
2-3.
2. If an error code is not displayed,
press
and hold the SELECT button
until
the display
changes.
Then,
press
the SELECT button
again
and hold until a flashing
SR code appears.
It must
show
SR27. If any other
number
shows,
the face plate computer
is working
on incorrect
input
and would
probably
be the cause of the problem.
To set SR27, press
either
the UP []
or DOWN
[]
button.
When
SR27 shows,
press
SELECT
to return
a
flashing
12:00 AM display.
Reset the present time, hardness
numbel,
etc., pages 1-3 and 1-4.
PROBLEM
CAUSE
CORRECTION
No soft water
No salt (or salt bridged) in the storage tank
Transfomer unplugged at the wall outlet,
or power cable leads loose, fuse blown,
circuit breaker popped, or circuit switched
off.
Manual bypass valve(s) in bypass position
Dirty, plugged
or damaged
nozzle
&
venturi
Valve drain hose plugged
Water hard sometimes
Hardness number setting too low
Using
hot
water
when
softener
is
regenerating
Increase in the grains of hardness in your
water supply
Refill with salt, or break the salt bridge (page
3-1).
Press
ON/OFF-HOLD
(RECHARGE
NOW) button and hold for 3 seconds to start a
regeneration (see page 2-1 ).
Check for loss of power due to any of these
and correct. With the power back on, look at
the
time
display
and
read
PROGRAM
MEMORY, page 2-3.
Look at FIG.14 on page 4-1. Move the stem in
a single valve to service. In a 3-valve bypass,
open the inlet and outlet valves, and be sure to
fully close the bypass valve.
Take apart and clean or replace damaged
parts (see page 3-2).
The drain hose must not have kinks, sharp
bends, or be raised too high above
the
softener
(see page 16 in your installation
manual).
Press and release the SELECT button until
HARDNESS shows in the display. Read the
hardness number in the display and be sure
the same grains per gallon number is shown
on your water analysis report. See page 1-4 to
reset. Press and release the SELECT button
until the present time shows in the display.
Avoid using hot water during this time because
the water heater refills with hard water (see
Automatic Bypass, page 2-6).
Ask your Sears retail store for a new water
analysis. Then make a new hardness number
setting (page 1-4).
3-4