Look atthetopofthewater h eater. Thecold water i nlet i s
marked "COLD". Put t wo orthree turns ofteflon tape around
thethreaded e ndofthethreaded-to-sweat
coupling a nd
around bothendsofthe3/4"NPT threaded n ipple. Using
flexible c onnectors, connect thecold water p ipe tothecold
water i nlet o fthewater h eater.
NOTE: This water heater is super insulated to minimize
heat loss from the tank. Further reduction
in heat loss
can be accomplished
by insulating the hot water lines
from the water heater.
INSTALLATION
COMPLETED
USING INSTALLATION
KIT
FLEXIBLE
WATER
CONNECTORS
NOT WATER
COLD WATER
OUTLET
INLET
t
t
SHUTOFF
VALVE
THREADED
TO
THREADED
TO
SWEAT COUPLING
SWEAT
COUPLING
3/4"THREADED
_
HEAT TRAP WITH
_
"41""""""-
314"THREADED
SECONDARY
COUPLING/HEAT
TRAP
ANODE
DRAFTHOOD
TEMPERATURE-
_PRESSURE
RELIEF VALVE
Fit T & P valve insulation over valve. Make sure that the insulation
does not interfere with the lever of the T & P valve.
Secure all insulation using tape.
Temperature-Pressure
Relief Valve
/
Explosion
Hazard
• Temperature-pressure
relief valve
must comply
with ANSI Z21.22
and ASME code.
• Properly
sized
temperature-
pressure
relief
valve
must
be
installed in opening provided.
• Can result
in overheating
and
excessive
tank pressure.
• Can cause serious injury or death.
This heater is provided with a properly certified combination
temperature
- pressure relief valve by the manufacturer.
The valve
is certified
by a nationally
recognized
testing
laboratory that maintains periodic inspection of production
of
listed equipment of materials as meeting the requirements
for
Relief Valves and Automatic Gas Shutoff Devices for Hot Water
Supply Systems, ANSI Z21.22 and the code requirements
of
ASME.
DISCHARGE PIPE
(Do not cap or plug)
FLOOR DRAIN
FIGURE 15.
T & P Valve and Pipe Insulation
Remove insulation for T & P valve and pipe connections from
carton.
PIPE
INSULATION
FLUE PIPE
T&P
)
RGURE 15A.
Fit pipe insulation over the incoming cold water line and the hot
water line. Make sure that the insulation
is against the top
cover of the heater.
13
If replaced, the valve must meet the requirements of local codes,
but not less than a combination
temperature
and pressure
relief valve certified as indicated in the above paragraph.
The valve must be marked with a maximum set pressure not to
exceed the marked hydrostatic working pressure of the water
heater (150 psi = 1,035 kPa) and a discharge capacity not less
than the water heater input rate as shown on the model rating
plate.
For safe operation of the water heater, the relief valve must not
be removed from its designated
opening nor plugged.
The temperature-pressure
relief valve must be installed directly
into the fitting of the water heater designed for the relief valve.
Position the valve downward
and provide tubing so that any
discharge will exit only within 6 inches (153 mm) above, or at
any distance below the structural floor, see Figure 16. Be certain
that no contact
is made with any live electrical
part.
The
discharge
opening
must not be blocked
or reduced in size
under any circumstances.
Excessive
length, over 30 feet
(9.14 m), or use of more than four elbows can cause restriction
and reduce the discharge capacity of the valve.
No valve or other obstruction is to be placed between the relief
valve and the tank. Do not connect tubing directly to discharge
drain unless a 6 inch air gap is provided.
To prevent bodily
injury, hazard to life, or property damage, the relief valve must
be allowed
to discharge
water
in quantities
should
circumstances
demand.
If the discharge pipe is not connected
to a drain or other suitable means, the water flow may cause
property damage.