Troubleshooting Items - Kenmore 153 Owner's Manual

Power miser 6 series 30/40/50 gallon 30/40 gallon short 30/40/50 gallon high altitude 30/40/50 gallon propane (lp.) 40/50 gallon propane (l.p.) high altitude
Hide thumbs Also See for 153:
Table of Contents

Advertisement

These guidelines
should beused b y aqualified
service agent, Call Sears Service at1-800-4-MY-HOME
(1-800-469-4663)
forassistance,
Inform t he associate
that t his isa"Flammable
Vapor Ignition Resistant"
Product,
Improperly
sealed, hot o rcold supply connection,
relief valve, drain v alve, orthermostat
threads.
Leakage
from other appliances
orwater lines.
Condensation
offlueproducts.
Thermal expansion
inclosed water system.
Improperly
seated valve.
Tighten threaded
connections.
WATER
LEAKS
Inspect other appliances
near water heater.
Refer to CONDENSATION.
Install thermal expansion tank (DO NOT plug T&P valve).
LEAKING
T&P VALVE
Check relief valve for proper operation
(DO NOT plug T&P valve).
High sulfate or mineral content in water supply.
Drain and flush heater thoroughly,
then refill.
SMELLY ODORS
Bacteria in water supply.
Chlorinate or aerate water supply.
Gas control knob not positioned
correctly.
Referto LIGHTING INSTRUCTIONS.
Main gas supply off.
Turn on main gas shutoff valve.
Igniter tip more than 1/8" from pilot hood.
Adjust igniter tip.
Thermocouple
malfunction.
Replace pilot assembly.
ThermocoupIe TCO malfunction.
Replace pilot assembly.
Melted insulation on igniter wire or shorting
Contact Sears Service to determine cause.
PILOT WILL NOT LIGHT
of igniter wire.
High ambient room temperature.
Contact Sears Service to determine cause.
Wire disconnected
from spark igniter.
Reconnect
wire connector to spark igniter.
Broken electrode or electrical wire.
Replace pilot assembly.
Piezo Igniter generator fails to operate or
Replace Piezo Igniter generator.
malfunctions.
Thermocouple TCO malfunction.
Replace pilot assembly.
High ambient room temperature.
Contact a service agency to
determine
cause.
BURNER WILL NOT
Dirty or clo_ed
air intake screen.
Clean and reinstall air intake screen.
STAY LIT
Flame arrestor openings blocked.
Contact Sears Service to
determine
cause.
Defective Gas Control.
Replace Gas Control.
Dirty pilot burner.
Clean pilot assembly.
Dirty or clogged air intake screen.
Clean and reinstall air intake screen.
PILOT OUTAGE
Thermocouple
tip is not in contact with pilot flame.
Insert thermocouple
correctly.
Thermocouple
malfunction.
Replace pilot assembly.
Thermocouple TCO malfunction.
Replace pilot assembly.
Defective Gas Control.
Replace Gas Control.
Heater not lit or thermostat not on.
Refer to LIGHTING INSTRUCTIONS.
Thermostat
set too low.
Referto TEMPERATURE REGULATION.
Heater undersized.
Reduce hot water use.
NOT ENOUGH
Low gas pressure.
Contact your gas supplier.
HOT WATER
Incoming water is unusually cold.
Allow more time for heater to re-heat.
Leaking hot water pipes or fixtures.
Have plumber check and repair leaks.
High temperature
limit switch activated.
Contact Sears Service to
determine
cause.
WATER TOO HOT
Thermostat set too high.
Refer to TEMPERATURE REGULATION.
WATER HEATERSOUNDS
Condensation
dripping on burner.
Refer to CONDENSATION.
Sediment or calcium in bottom of heater tank.
Clean sediment from tank. Refer to DRAINING
SIZZLING
- RUMBLING
instructions
in Maintenance
section of manual.
SOOTING
Improper combustion.
No adjustment available.
Contact Sears Service
1o deten*nine cause.
Lack of supply air.
Improperly installed vent piping.
Downdraft.
Poor combustion.
VENTGASODORS
Contact Sears Service to determine cause.
26