Troubleshooting Items - Kenmore POWER MISER 153.331280 Owner's Manual

Ultra low nox gas water heater 40 & 50 gallon
Table of Contents

Advertisement

PROBLEM
BURNER WILL NOT IGNITE
POSSIBLE CAUSE(S)
1.
Pilot not tit
2.
Thermostat set too low
3.
No gas
4.
Dirt in the gas lines
5.
Pilot tine clogged
6.
Main burner line clogged
7.
Non-functioning
thermocouple
8.
Non-functioning
thermostat
9.
Heater installed in a confined area
CORRECTIVE
ACTION
1.
Light pilot
2.
Turn temp. dial to desired temperature
3.
Check with gas utility company
4.
Notify utility-install trap in gas line
5.
Clean, locate source and correct
6.
Clean, locate source and correct
7.
Replace thermocouple
8.
Replace thermostat
9.
Provide fresh air ventilation
SMELLY WATER
1.
Sulfides in the water
1.
Replace the anode with a special anode
PILOT WILL NOT LIGHT
1.
Air in gas line
2.
No gas
3.
Dirt in gas lines
4.
Pilot line or orifice clogged
5.
Cold drafts
6.
Thermostat
ECO switch open
7.
Non-functioning
igniter
8.
Flammable vapor incident
9.
Low gas pressure
10. Air for combustion obstructed
PILOT WILL NOT REMAIN LIT
HIGH OPERATION COSTS
11. Pilot dirty
1.
Air in gas line
2.
Dirt in gas lines
3.
Pilot tine or orifice clogged
4.
Thermocoupte
connection loose
5.
Non-functioning
thermocouple
6.
Cold drafts
7.
Flammable vapor incident
8.
Low gas pressure
9.
Air for combustion obstructed
10. Pilot dirty
1.
Thermostat set too high
2.
Sediment or lime in tank
3.
Water heater too small for job
4.
Wrong piping connections
5.
Leaking faucets
6.
Gas leaks
7.
Wasted hot water
8.
Long runs of exposed piping
9.
Hot water piping in exposed wall
1.
Thermostat set too tow
2.
Sediment or lime in tank
3.
Water heater too small
4.
Wrong piping connections
5.
Leaking faucets
6.
Wasted hot water
7.
Long runs of exposed piping
8.
Hot water piping in outside wall
9.
Low gas pressure
1.
Insufficient
air
2.
Flue clogged
3.
Low gas pressure
4.
Improper calibration
5.
Thermostat set too tow
6.
Water heater too small
7.
Wrong piping connections
8.
Wasted hot water
INSUFFICIENT
HOT WATER
SLOW HOT WATER
RECOVERY
1.
Bleed the air from the gas line
2.
Check with gas utility company
3.
Notify utility-install dirt trap in gas line
4.
Clean, locate source and correct
5.
Locate source and correct
6.
Replace thermostat
7.
Replace igniter pilot assembly
8.
Eliminate flammable vapor source(s)
Call 1-800-4-MY-HOME ® (1-800-469-4663)
9.
Check with gas utility company
10. See service and adjustment section for
inspection and cleaning of flame arrestor
& burner
11. Clean pilot
1.
Bleed the air from the gas line
2.
Notify utility-install dirt trap in gas line
3.
Clean, locate source and correct
4.
Finger tighten; then 1/2 turn with wrench
5.
Replace thermocoupte
6.
Locate source and correct
7.
Eliminate flammable vapor source(s)
Call 1-800-4-MY-HOME ® (1-800-469-4663)
8.
Check with gas utility company
9.
See service and adjustment section for
inspection and cleaning of flame arrestor
& burner
10. Clean pilot
1.
2.
Set temperature dial to lower setting
Drain/flush-provide
water treatment if
needed
3.
Install adequate heater
4.
Correct piping-dip tube must be in cold
inlet
5.
Repair faucets
6.
Check with utility-repair at once
7.
Advise customer
8.
Insulate piping
9.
Insulate piping
1.
Turn temperature dial to desired setting
2.
Drain/flush-provide
water treatment if
needed
3.
Install adequate heater
4.
Correct piping-dip tube must be in cold
inlet
5
Repair faucets
6.
Advise customer
7.
Insulate piping
8.
Insulate piping
9.
Check with gas utility company
1.
Provide ventilation to water heater.
Check flue way, flue baffle, and burner
2.
Clean flue, locate source and correct
3.
Check with gas utility company
4.
Replace thermostat
5.
Turn temperature dial to desired setting
6.
Install adequate heater
7.
Correct piping-dip tube must be in cold
inlet
8.
Advise customer
28

Advertisement

Table of Contents
loading

Table of Contents