    Table of Contents 1.0 General ..................... 3 2.0 RTS Matrix to IP-223 Cabling .............. 4 3.0 LMR Configuration Example ..............5 3.1 IP-223 Setup ......................5 3.1.1 Multicast Address Setup Window ..............6 3.1.2 Crosspatch Setup Window .................7 3.1.3 Per Line Setup Window Line 1 ..............7 3.1.4 Per Line Setup Window Line 2 ..............8 4.0 iDEN Configuration Example ...............
  • Page 3: General

    IP-223 to RTS Intercom Products 1.0 General This application note demonstrates how to configure and connect the Telex Dispatch IP-223 Remote Adapter Panel panel to an RTS Intercom System. This interface provides PTT (Push To Talk) control and audio connections from most LMRs (Land Mobile Radio) to the operator keypanels.
  • Page 4: Rts Matrix To Ip-223 Cabling

    IP-223 to RTS Intercom Products 2.0 RTS Matrix to IP-223 Cabling The RTS Matrix to IP-223 cabling diagram, shown in Figure 1, illustrates pinouts used to connect an RTS Intercom to a Telex IP-223 Adapter Panel. RTS documents are available at: http://www.rtsintercoms.com/manuals/php. NOTE:...
  • Page 5: Lmr Configuration Example

    IP-223 to RTS Intercom Products 3.0 LMR Configuration Example A line to line configuration example using an LMR is shown in Figure 2. The line to line crosspatch is enabled in the IP-223. Control logic and audio (6-wire E&M) are generated by the RTS system;...
  • Page 6: Multicast Address Setup Window

    IP-223 to RTS Intercom Products 3.1.1 Multicast Address Setup Window The Multicast Address Setup window, shown in Figure 3, is used to configure the line type for Lines 1 and 2. To configure Lines 1 and 2 for an LMR configuration, do the following.
  • Page 7: Crosspatch Setup Window

    IP-223 to RTS Intercom Products 3.1.2 Crosspatch Setup Window The Crosspatch Setup window, shown in Figure 4, is used to set up a crosspatch. To enable crosspatching, do the following: 1. Click CRP Setup. The Crosspatch Setup window appears. 2. Select the Enable Line-Line check box.
  • Page 8: Per Line Setup Window Line 2

    IP-223 to RTS Intercom Products 3.1.4 Per Line Setup Window Line 2 The Per Line Setup window, shown in Figure 5, is used to setup the connection to the RTS equipment. Depending on the connection to the RTS equipment, VOX or COR triggering may be used.
  • Page 9: Iden Configuration Example

    IP-223. Control logic and audio (6-wire E&M) are generated by the RTS system; these are connected to Line 2 I/O which is configured for local mode operation. Line 1 I/O of the IP-223 is also configured for local mode operation with iDEN as the selected radio. A Telex NI-223 is required for this interface.
  • Page 10: Multicast Address Setup Window

    IP-223 to RTS Intercom Products 4.1.1 Multicast Address Setup Window The Multicast Address Setup window, shown in Figure 7, is used to configure the line type. To configure an iDEN type on Line 1, do the following. 1. Click Multicast Address Setup.
  • Page 11: Crosspatch Setup Window

    IP-223 to RTS Intercom Products 4.1.2 Crosspatch Setup Window The Crosspatch Setup window, shown in Figure 4, is used to enable line-to-line crosspatching. To enable a crosspatch for an iDEN radio, do the following: 1. Click CRP Setup The Crosspatch Setup window appears.
  • Page 12 IP-223 to RTS Intercom Products For more information, see the NI-223+ Technical Manual REFERENCE: (P/N 804165) for jumper settings and alignment procedures for Line 1. FIGURE 8. Per Line Setup Window, iDEN Radio–Line 1 AN-DISPATCH-035...
  • Page 13: Per Line Setup Window Line 2

    IP-223 to RTS Intercom Products 4.1.4 Per Line Setup Window Line 2 The Per Line Setup window for Line 2, shown in Figure 9, is used to set up COR or VOX triggering and audio levels. Depending on the connection to the RTS equipment, VOX or COR triggering may be used.
  • Page 14 IP-223 to RTS Intercom Products FIGURE 9. Per Line Setup Window, Local Mode–Line 2 AN-DISPATCH-035...
  • Page 15: Wan/Lan Remote Configuration Example

    IP-223 to RTS Intercom Products 5.0 WAN/LAN Remote Configuration Example The Telex IP-223 Adapter Panel can be employed to provide access to remote radio devices over a LAN or WAN. See Figure 10. Receive audio from the LMR, or iDEN handset, is connected to the line’s I/O (DB-25) of the remote IP-223.
  • Page 16: Local Ip-223 Multicast Address Setup Window

    IP-223 to RTS Intercom Products 5.1.1 Local IP-223 Multicast Address Setup Window Both Unicast and Multicast are supported for this feature. NOTE: See examples shown in Figure 11 and Figure 13. To configure a unicast system, do the following: 1. From the local IP-223 configuration webpage, click Multicast Address Setup.
  • Page 17 IP-223 to RTS Intercom Products To configure the Rx and Tx port numbers, do the following: > From the local IP-223 Multicast Address Setup window, in: • Line 1’s Rx Port field, enter an Rx port number for Line 1 (for example 1054).
  • Page 18: Local Ip-223 Per Line Setup Window Lines 1 & 2

    IP-223 to RTS Intercom Products 5.1.2 Local IP-223 Per Line Setup Window Lines 1 & 2 Depending on the connection to the RTS equipment, VOX or COR triggering maybe used. To configure an RTS supplied relay closure for a WAN/LAN system, do the following: 1.
  • Page 19: Ip-223 Remote Setup

    IP-223 to RTS Intercom Products 5.2 IP-223 Remote Setup The remote IP-223 must be configured for local mode operation on both lines. The IP-223’s default username is admin and the password is blank. NOTE: For more information, see the IP-223 Technical Manual (P/N803641) for REFERENCE: jumper settings relevant to the RTS equipment to be connected.
  • Page 20: Remote Ip-223 Per Line Setup Windows Line 1 And 2

    IP-223 to RTS Intercom Products To configure the Rx and Tx port numbers, do the following: From the remote IP-223 Multicast Address Setup window, in: 1. Line 1’s Rx Port field, enter the same port number as the local IP-223’s Tx port number for Line 1 (for example 1072).
  • Page 21: Remote Tone Control Configuration Example

    Industry standard radio control tones are generated and coupled with voice audio for control of distant radio locations. Control tones are decoded by either a Telex TRA-223 or DSP-223 Tone Remote Adaptor which is directly connected to the LMR radio.
  • Page 22: Multicast Address Setup Window

    IP-223 to RTS Intercom Products 6.1.1 Multicast Address Setup Window To configure the IP-223 for remote tone control, do the following: 1. Click Multicast Address Setup. The Multicast Address Setup window appears. 2. From the Line Type drop down menu for Line 1, select Tone Mode.
  • Page 23: Per Line Setup Window Line 1

    IP-223 to RTS Intercom Products 6.1.2 Per Line Setup Window Line 1 The Per Line Setup window, shown in Figure 16, require no changes although, various fields and options can be set based on the line type being configured. For more information, see the IP-223 Technical Manual REFERENCE: (P/N 803641).
  • Page 24: Per Line Setup Window Line 2

    IP-223 to RTS Intercom Products 6.1.3 Per Line Setup Window Line 2 Depending on the connection to the RTS equipment, VOX or COR triggering may be used. If a relay closure from the RTS equipment is supplied, the COR Enabled check box must be selected on Line 2’s Per Line Setup window.
  • Page 25 IP-223 to RTS Intercom Products To configure PTT with VOX for a remote tone control system, do the following: 1. Click Per Line Setup. The Per Line Setup window appears. 1. In the LAM Level dB field, enter the level in dB.
  • Page 26: Radio Connection Chart

    IP-223 to RTS Intercom Products 7.0 Radio Connection Chart Table 1 lists popular radios supported.by the IP-223. Telex Cable Manufacturer’s Telex Application Manufacturer Line Qty Assy P/N or Model Number Note Product BK/Relm AN-DISPATCH-017 BK/Relm RM Series AN-DISPATCH-019 Datron Guardian...
  • Page 27 IP-223 to RTS Intercom Products Table 2 lists cable assemblies required to connect the specified device to a Telex V.I.P.E.R. Cable Manufacturer Model Line Qty Assembly Application Note or Product Tactical Radios URC and PRC 400100161 LPX, LPU, LPH, 400100093...
  • Page 28 IP-223 to RTS Intercom Products AN-DISPATCH-035...
  • Page 29 Revision History Document Title: IP-223 to RTS Intercom Products Document Number: AN-DISPATCH-035 Revision Change Description Date Initial Release 05-AUG-2009 Suggestions or comments: Contact technical support with suggestions or comments concerning this application note. Technical Support: Email: TelexDispatchtechsupport@us.bosch.com Fax: 1-402-467-3279 Phone: 1-800-898-6723 Bosch Security Systems, Inc.