NuTone 8310 Installation Instructions

NuTone 8310 Installation Instructions

8 ̋ round fan
Hide thumbs Also See for 8310:

Advertisement

Quick Links

8˝ Round Fan
MODEL: 8310

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE.
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
service panel and lock service panel to prevent power from
being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
B. Sufficient air is needed for proper combusition and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application.
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
F. NEVER place a switch where it can be reached from a tub
or shower.
• Do not mount over tub or in shower enclosure.
• Suitable for use with solid-state speed controls.
If the installation presents a problem that is not explained
here or if any parts of these instructions are not clear, consult
a professional installer. If you are not familiar with methods of
installing electrical wiring, or if you are not certain as to the
correctness of any step or procedure described, secure the
services of a qualified electrician.
INSTALLING THE HOUSING
• Cutout dimension: 9" diameter
• Blade Size: 8"
1
• Grille Diameter: 10
"
2
MPORTANT: Remove shipping tape that secures louver.
1. Slide hanger bars (adjustable for 24" O.C. joists) through
tabs in housing. Nail one hanger bar to joist and slide
ventilator to desired position. Nail second hanger bar to
joist: cocking it slightly to clamp fan into place.

Advertisement

loading

Summary of Contents for NuTone 8310

  • Page 1: Important Safety Instructions

    INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS! 8˝ Round Fan MODEL: 8310 IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer.
  • Page 2 MAKING CONNECTIONS IMPORTANT: Prior to making wiring connections, JUNCTION disconnect electrical power at the main source and leave it off until the installation is complete. All wiring must comply with electrical codes. 1. Refer to Figure 1. Place wiring into the outlet box. Secure the connections with approved wire connectors and replace the cover plate.
  • Page 3: Maintenance And Cleaning

    FINAL ASSEMBLY INSTRUCTIONS 1. Check louvers in fan housing and outside wall cap to see that they are not damaged or binding. Louvre can be readily removed by depressing spring bearings on end of hinge pins. Refer to Figure 5. Install motor and blade assembly into housing.
  • Page 4: One Year Limited Warranty

    WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.