Overvoltage Conditions - Siemens S6 GSM Service Manual

Private communication systems mobile phones
Hide thumbs Also See for S6 GSM:
Table of Contents

Advertisement

Furthermore the ASIC generates the supply voltage for the SIM-Card and the RESET
signal for the logic devices.
The ASIC also checks the presence of the watchdog signal from the P and provides
the switching on functionality (ON_OFF button or Ignition signal).
During testing ist is advisable to use a battery dummy, connected to a power supply
delivering +4V, max 3A.
Make sure that you connect the battery dummy with the right polarity, the red plug to
+4V and the blue plug to ground.
If you use a voltage higher than +7V, or with wrong polarity, the phone can be
destroyed!

5.4 Overvoltage Conditions

a) Battery Voltage:
b) Charging Current:
-> Be careful with foreign accessories or chargers!
-> Make sure that the charging current is limited to a value below 1A!
V1.3
If the battery voltages rises above 6.2 Volts, the phone will
switch off and it cannot be switched on again before the
voltage is lower than 6.2 Volts.
If the battery voltage rises above 7 Volts the phone can be
destroyed.
The charging current must not rise above 1 A or the
phone (fuse) will be inoperable.
15
Private Communication Systems
Mobile Phones
PN MP ST
D. Schnoor
10/97

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S6 pcn

Table of Contents