Sony MZ-E10 Service Manual page 16

Hide thumbs Also See for MZ-E10:
Table of Contents

Advertisement

MZ-E10
2. Insert CD disc in the set, and press . key to set the Overall
CD Adjustment mode.
Automatic adjustments are made.
LCD display
XXX CD RUN
XXX: Item No. for which an adjustment is being executed.
3. If NG in the overall CD adjustments, return to Reset NV and
perform from the overall CD adjustment again.
LCD display
000 XXX NG YY
XXX: NG item No.
YY: adjusted valive.
4. If OK through the overall CD adjustments, then perform overall
MO adjustments.
LCD display
000 CD OK
5. Insert MO disc in the set, and press
MO Adjustment mode. Automatic adjustments are made.
LCD display
XXX MO RUN
XXX: Item No. for which an adjustment is being executed.
6. If NG in the overall MO adjustments, return to NV initiale and
perform from the overall CD adjustments again.
LCD display
000 XXX NG YY
XXX: NG item No.
YY: adjusted valive.
7. If OK through the overall MO adjustments, press
return to the test mode.
LCD display
000 MO OK
5-7-4.Resume clear method
When the battery exchange isn't being done.
1. Setting the testmode.
2. Set the Manual mode and set the item No.043(RESUME Clear).
LCD display
043 Resume 00
16
key to set the Overall
>
key to
x
3. Press the
key.
LCD display
043 Res ***
LCD display
043 Res C1r
5-7-5.Resume clear method
When the battery exchange was done.
1. Setting the testmode.
2. Set the Manual mode and set the item No.043(RESUME Clear).
LCD display
043 Resume 00
3. Press the
key two times, and set the adjustment value
VOL +
to 02.
043 Res
4. Press the
key.
LCD display
043 Res ***
LCD display
043 Res C1r
5-7-6. Overall CD and MO adjustment items
1. Overall CD adjustment items
Item No.
312
ALFA offsetadjustment
313
IJ offset adjustment
314
FE offset adjustment
320
Focus servo ON
324
TE offset adjustment
321
TE gain adjustment
328
TWPP gain adjustment
twpp-gain[H]+4 t twpp-gain[L]
824
324
TE offset adjustment
330
Tracking servo ON
336
ABCD gain adjustment
337
KF gain adjustment
338
RF gain adjustment
344
CD focus gain adjustment
345
CD tracking gain adjustment
521
CD two-axis sensitivity adjustment (inside)
522
CD two-axis sensitivity adjustment (outside)
After reset is completed
02
After reset is completed
Contents

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents