TYPICAL WIRING DIAGRAMS  
These diagrams relate only to the components listed. Others may vary in their wiring requirements, particularly thermostats. 
Always refer to manufacturers' instructions which may override the detail in order to function correctly.  
WIRING DIAGRAM 2 x TWO PORT ZONE VALVES (S‐
PLAN) VARIANT DUAL THERMOSTAT WIRING  
Zone Valve (Htg)
Room Stat
HP22
RMT 230
G
Br
Bl
O
1
2
1
2
Power
Supply
E
N
L
1
2
3
4
5
Junction Box
1
2
3
2
4
3
L
N
Htg
Dhw
L
N
E
L
N
on
on
FP75 or CP15 Programmer
Basic Boiler
 
COMMISSIONING  
FILLING 
First you must ensure that the pressure in the expansion vessel is the same as the setting of the pressure reducing valve i.e. 3 
bar (45PSI). The valve is of the Schrader car tyre type. Check all the connections for water tightness including any factory made 
connections  such  as  the  immersion  heater  and  the  temperature  and  pressure  relief  valve.  Prior  to  filling,  open  the  hot  tap 
furthest away from the BIASI SILVER to expel air. Open the cold main isolation valve and allow the unit to fill.  
Once the cylinder as been fully commissioned should be heated to its normal operating temperature. Draw off secondary hot 
water to each outlet and allow hot water to flow from each outlet for at least 30 seconds to remove any flux residue from the 
pipe work within the secondary hot water system. Then fully drain the cylinder and re‐filled to ensure that all flux residues is 
removed from the system. 
 
DIRECT UNITS  
After both filling with water and purging of sterilisation liquid, switch on the power to the immersion heaters and allow the unit 
to start to heat. The immersion heater is supplied preset at 55°C. Turning fully to + sets to approx 65°C. 
 
INDIRECT UNITS 
Fill the primary circuit according to the boiler manufacturers' commissioning instructions. Ensure the lever on the two port valve 
is set to the filling position. When full, move the lever back. Switch the programmer to Domestic Hot Water (DHW) and allow 
the unit to start to heat. Adjust the dial of the dual thermostat to between 30°C and 70°C as required. 
 
STORAGE TEMPERATURE 
60‐65°C  is  the  recommended  storage  temperature  for  both  direct  and  indirect  cylinders.  In  hard  water  areas  consideration 
should be given to reducing this to 50‐55°C. In many healthcare applications the guidance on Legionella control and safe water 
delivery temperatures will require storing the water at 60‐65°C, distributing at 50‐ 55°C and using thermostatic mixing valves to 
control the final temperature. For details consult the NHS Estates Guidance on safe hot water temperatures. 
 
 
 
Zone Valve (Dhw)
HP22
4
G
Br
Bl
O
Dual Stat
2
1
2
1
2
High Limit
6
7
8
9
10
3
L
E
2
N
E
E
3
Pump
 
unvented hot water cylinders  
installation and maintenance instructions
WIRING DIAGRAM THREE PORT MID POSITION 
VALVE (Y‐PLAN) + TWO PORT VALVE VARIANT 
DUAL THERMOSTAT WIRING 
Room Stat
RMT 230
1
2
4
IDT
2
Control
C
Power
Supply
E
N
C
L
Unit
Stat
1
2
3
Junction Box
1
2
3
NOT
L
N
4
USED
Htg
L
N
E
on
FP75 or CP15 Programmer
 
Cylinder Stat
Mid Position Valve
ITD Dual Stat
HP22
C
2
1
W
G
O
BI
G/Y
2
3
4
5
6
7
8
9
10
2
3
L
3
1
L
N
E
2
N
E
Dhw
Dhw
L
N
E
on
off
3
Pump
Basic Boiler