SOLAR CONTROLLER AND SOLAR MONITOR
DIAGNOSTIC FEATURES OF THE SOLAR CONTROLLER
The operational modes are:
Flashes
Operational Modes
solid green
Standby mode
(remains on)
green
Standby mode
slow pulse
(power on for less than 48 hours)
green
Circulating water through collectors
rapid pulse
Circulating water through collectors
3 x green
(power on for less than 48 hours)
no green
Power outage or call for service
(remains off)
Flashes
Fault Modes
red
Temperature rise across collector greater than 40°C
rapid pulse
(circulator at full speed)
3 x red
Hot sensor in collector – short circuit
4 x red
Hot sensor in collector – open circuit
5 x red
Cold sensor –short circuit
6 x red
Cold sensor – open circuit
If the power supply to the solar control unit is on and the green LED is off or the
red LED is flashing, this indicates there may be a fault with the water heater.
The red LED may emit up to six flashes in each series of flashes.
Note: During periods of high solar radiation and if the circulator activates after
having been off, such as during start up, it is possible the red LED may emit a
rapid pulse for a period of up to ten (10) minutes. This does not indicate a fault.
Refer to
"Commissioning"
flashing sequence during start up procedure.
If the red LED continues to emit a rapid pulse for longer than ten (10) minutes,
or emits a series of flashes, then count the number of flashes and phone your
nearest Service Department or Accredited Service Agent to arrange for an
inspection.