Viessmann Vitodens 100-W Installation And Service Instructions Manual page 34

9.0 to 35.0 kw wall mounted gas fired condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 100-W:
Table of Contents

Advertisement

Troubleshooting
Fault messages on the display
Fault code
System characteris-
on the dis-
tics
play
51
No DHW heating
52
Burner blocked
58
No DHW heating
59
No DHW heating
5A
Burner blocked
A9
Regulated operation
without Open Therm
device
b0
Burner blocked
b8
Burner blocked
E5
Burner blocked
F0
Burner blocked.
F1
Burner in a fault
state
34
(cont.)
Cause
Measures
Outlet temperature
Check the sensor (see
sensor shorted out
page 43).
Short circuit, flow
Check connections and
sensor
lead; replace sensor if
required.
Cylinder tempera-
Check the sensor (see
ture sensor lead
page 40).
broken
Outlet temperature
Check the sensor (see
sensor lead broken
page 43).
Break, flow sensor Check connections and
lead; replace sensor if
required.
Communication
Check connections and
fault Open Therm
lead; replace Open Therm
device
device if required.
Short circuit, flue
Check the sensor (see
gas temperature
page 44).
sensor
Break, flue gas
Check the sensor (see
temperature sen-
page 44).
sor
Internal fault
Check the ionisation elec-
trode and cables.
Press "Reset" (see
page 36).
Internal fault
Replace the control unit.
Max. flue gas tem-
Check the heating system
perature exceeded
fill level. Check the circu-
lation pump. Vent the sys-
tem.
Press "Reset" (see
page 36).