Sanyo SAP-KRV9AEH Service Manual page 40

Dc inverter split system air conditioner
Hide thumbs Also See for SAP-KRV9AEH:
Table of Contents

Advertisement

8-4-4. Malfunction diagnosis of start-up failure
< Main Detection Points >
Is wiring of compressor correct ?
Is the stop time of compressor enough ?
Is compressor damaged ?
< Malfunction Diagnosis Process >
Energize the unit and
start it.
Is the stop time
of compressor more
than 3 min ?
Yes
No
Start-up failure ?
Yes
Is compressor
wire connected
correctly ?
Yes
Replace parts if outdoor
electric box is defective.
Remove the error ?
No
Replace compressor.
Finish
No
Start it 3 min later.
No
Connect it according to
line chart.
Yes
40

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-crv9aehSap-krv12aehSap-crv12aeh

Table of Contents