Operation; Cleaning And Maintenance; Troubleshooting - Broan XB50 Installation Manual

Single-speed ventilation fan
Hide thumbs Also See for XB50:
Table of Contents

Advertisement

Page 12
WARNING
Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.

Operation

To Operate Fan
Use an ON/OFF switch to operate this ventilator.

Cleaning and Maintenance

To Clean
For quiet and efficient operation, long life and attractive
appearance, remove Grille and vacuum interior of unit
with a dusting brush attachment.
The Motor is permanently lubricated and never needs
oiling. If the motor bearings are making excessive or
unusual noises, replace the Control Assembly and Motor.
XB50

Troubleshooting

Symptom: The fan does not run.
• Check for an open fuse or circuit breaker in the
building's service panel.
• Check that the two (2) plug-in connections for the Motor
and the Control are seated firmly in place.
• Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically.
• Check that the Blower Wheel is firmly attached to the
Motor shaft and both spin freely.
Symptom: The fan seems noisy.
• Check that the back draft damper in the fan's Duct
Connector pivots freely. Screws used to attach the duct
to the Duct Connector may be preventing the damper
from opening.
• Check that the back draft damper in the wall or roof cap
pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris..
XB80
XB110 Installation Guide
n
n

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xb80Xb110

Table of Contents