READ AND SAVE THESE INSTRUCTIONS
Installer: leave this guide with homeowner.
Easy installation in both
new construction and retrofit
© 2017 Broan
XB110HL1
X1 | Single-Speed Ventilation
Fan with Dimmable Light
and Humidity Sensor
INSTALLATION GUIDE

Table of Contents

2
2
3
7
12
13
13
13

Advertisement

loading

Summary of Contents for Broan ULTRA GREEN XB110HL1

  • Page 1: Table Of Contents

    Fan with Dimmable Light and Humidity Sensor INSTALLATION GUIDE Table of Contents Warnings and Cautions Typical Installation New Construction Installation Easy installation in both Retrofit Installation Operation new construction and retrofit Cleaning and Maintenance Troubleshooting Service Parts © 2017 Broan...
  • Page 2: Warnings And Cautions

    Page 2 XB110HL1 Installation Guide WARNING CAUTION TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR . For general ventilating use only. Do not use to exhaust INJURY TO PERSONS, OBSERVE THE FOLLOWING: hazardous or explosive materials and vapors. 1. Use this unit only in the manner intended by the manufacturer. 2.
  • Page 3: New Construction Installation

    Page 3 XB110HL1 Installation Guide New Construction Installation Tools needed Materials needed • Power screwdriver with a Phillips bit • 6" round metal ducting recommended for best performance. Use of other ducting is acceptable but may impact performance. • Phillips screwdriver •...
  • Page 4 Page 4 XB110HL1 Installation Guide New Construction Installation Snap-in and Secure Housing Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place. Do not crimp Housing. Screws from Parts Bag Attach Duct Connector and Ducting Top and bottom flanges Screw from go outside Housing...
  • Page 5 Page 5 XB110HL1 Installation Guide New Construction Installation Connect Wires and Install Knockout Plate • Run 120VAC electrical wiring to the installation location. • Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag. • Connect wires as shown in wiring diagram. Attach cable clamps to Knockout Plate.
  • Page 6 Page 6 XB110HL1 Installation Guide New Construction Installation Insert Mask and Finish Ceiling • Install ceiling material. • Cut out around Housing. CAUTION IN ORDER TO PREVENT Mask protects unit MOTOR/CONTROL DAMAGE: during construction. If the blower was unplugged, power must be Remove before installing Grille.
  • Page 7: Retrofit Installation

    Page 7 XB110HL1 Installation Guide Retrofit Installation Tools needed Materials needed • Power screwdriver with a Phillips bit • Ruler • Tape to seal duct connections • Phillips screwdriver • Pencil • Existing rigid duct will require the addition of a short length of flexible duct •...
  • Page 8 Page 8 XB110HL1 Installation Guide Retrofit Installation Remove Blower Assembly Set aside Blower Assembly Both sides Remove Wiring Panel Set aside Wiring Panel Set aside screw Insert Mounting Frame Remove screws from Mounting Frame Bend up and set aside four tabs...
  • Page 9 Page 9 XB110HL1 Installation Guide Retrofit Installation Secure Mounting Frame Screws set aside in Step 7 Snap-in Housing Pull existing wiring into Housing as it is inserted into Mounting Frame Attach Ducting and Duct Connector Screw from Parts Bag Pull existing ductwork into Housing Insert tab into...
  • Page 10 Page 10 XB110HL1 Installation Guide Retrofit Installation Install Knockout Plate, Connect Wires and Reinstall Wiring Panel • Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag. • Connect wires as shown in wiring diagram. Attach cable clamps to Knockout Plate.
  • Page 11 Page 11 XB110HL1 Installation Guide Retrofit Installation Reinsert and Secure Blower Assembly CAUTION IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE: Power must be disconnected (see page 2, WARNING item 2) before inserting motor plugs into control assembly. Screws from Parts Bag If ceiling repairs are needed, place Mask in Housing after Blower Assembly is secured.
  • Page 12: Operation

    Page 12 XB110HL1 Installation Guide Time Delay: WARNING Before servicing or cleaning unit, Fan continues to run until user-adjustable TIME delay has switch power off at service panel and lock the service passed, then fan turns off. disconnecting means to prevent power from being To Set User-Adjustable Humidity Sensitivity** switched on accidentally.
  • Page 13: Cleaning And Maintenance

    Page 13 XB110HL1 Installation Guide Cleaning and Maintenance Service Parts CAUTION IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE: DO NOT remove motor plug to stop spinning motor. Power must be disconnected (see WARNING on previous page) before motor plug is removed or inserted into control assembly.