Broan PM250 SERIES Instructions For Assembly Operation
Broan PM250 SERIES Instructions For Assembly Operation

Broan PM250 SERIES Instructions For Assembly Operation

Power module
Hide thumbs Also See for PM250 SERIES:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

POWER
MODULE
REGISTER YOUR PRODUCT ONLINE AT www.broan.com/register
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or tele-
phone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock service panel to prevent power from being switched on
accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equipment manufacturer's
guidelines and safety standards such as those published by the Na-
tional Fire Protection Association (NFPA), and the American Soci-
ety for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any separate solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on
low or medium settings.
B. Always turn hood ON when cooking at high heat or when flambeing
food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef
Flambe').
C. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
D. Use proper pan size. Always use cookware appropriate for the size
of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
READ AND SAVE THESE INSTRUCTIONS
!
INTENDED FOR DOMESTIC COOKING ONLY
!
CAUTION
1. For indoor use only.
2. To reduce risk of fire and to properly exhaust air, be sure to duct air
outside. Do not vent exhaust air into spaces within walls or ceilings or
into attics, crawl spaces, or garages.
3. Take care when using cleaning agents or detergents.
4. Avoid using food products that produce flames under the Range Hood.
5. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
6. To avoid motor bearing damage and noisy and/or unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power unit.
7. Your hood motor has a thermal overload which will automatically shut
off the motor if it becomes overheated. The motor will restart when it
cools down. If the motor continues to shut off and restart, have the
hood serviced.
8. For best capture of cooking impurities, the bottom of the hood should
be a minimum of 24" and a maximum of 30" above the cooking
surface.
9. Two installers are recommended.
10. Use with approved cord-connection kit only.
11. Please read specification label on product for further information and
requirements.
PM250 SERIES
!

Advertisement

Table of Contents
loading

Summary of Contents for Broan PM250 SERIES

  • Page 1 PM250 SERIES POWER MODULE REGISTER YOUR PRODUCT ONLINE AT www.broan.com/register READ AND SAVE THESE INSTRUCTIONS INTENDED FOR DOMESTIC COOKING ONLY WARNING CAUTION 1. For indoor use only. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 2. To reduce risk of fire and to properly exhaust air, be sure to duct air TO PERSONS, OBSERVE THE FOLLOWING: outside.
  • Page 2: Install The Ductwork

    INSTALL THE DUCTWORK NOTE: To reduce the risk of fire, use only metal ductwork. 1. Decide where the ductwork will run between the hood and the outside (Refer to Figure 1). 2. A straight, short duct run will allow the hood to perform most efficiently.
  • Page 3: Operation

    OPERATION SERVICE PARTS Controls Light switch: turns the lamps on and off. KEY NO. PART NO. DESCRIPTION Blower switch: makes it possible to select the motor operating speed. B03118152 Grid (White) Position 0: motor off; Position I: motor lower speed; Position II: motor B03127681 Grid (Silver) high speed.
  • Page 4: Warranty

    WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 5 SÉRIE PM250 MODULE DE HOTTE ENCASTRABLE ENRÉGISTER VOS PRODUITS ONLINE À www.broan.com/register LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR UTILISATION DOMESTIQUE SEULEMENT B. L’incendie est petit et limité à l’endroit où il a débuté. AVERTISSEMENT C. Les pompiers ont été avisés.
  • Page 6: Installation Du Module

    INSTALLATION DU SYSTÈME DE CONDUITS NOTE : Pour réduire les risques d’incendie, n’utilisez que des conduits en métal. 1. Déterminer par où passera le conduit, entre votre module et l’extérieur (Réf. Figure 1). 2. Un conduit droit et court permettra à votre module de fonctionner plus efficacement.
  • Page 7: Entretien

    FONCTIONNEMENT LISTE DES PIÈCES DE RECHANGE Commandes L’interrupteur d’éclairage allume et éteint les lampes. PART N. DESCRIPTION L’interrupteur du ventilateur permet de sélectionner la vitesse B03118152 Grille (Blanche) de fonctionnement. Position 0 : ventilateur arrêté; Position I : basse B03127681 Grille (Argent) B08087922 Filtre à...
  • Page 8: Garantie

    La présente garantie remplace toutes les autres garanties précédentes. Pour le service sous garantie, vous devez (a) aviser Broan-NuTone à l'une des adresses ou numéros de téléphone mention- nés ci-dessous, (b) indiquer le numéro de modèle et d'identification de la pièce et (c) décrire la défectuosité du produit ou de la pièce.

Table of Contents