PRE-DELIVERY INSPECTION
7) Press the "UNLOCK" button momentarily on the
keyless transmitter. Check that the driver's door is
unlocked and hazard light blinks twice and room
light is lit for 15 seconds.
And press the "UNLOCK" button momentarily
again in 5 seconds (except for EK model). Check
that all the doors including rear gate are unlocked.
8) Close all the doors including rear gate and press
the "LOCK" button on the keyless transmitter.
Press the "OPEN" button on the keyless transmitter
and wait for 25 seconds. Check if all the doors in-
cluding rear gate are locked. (Except for EK model)
23.SEAT
1) Check the seat surfaces for stains or dirt.
2) Check that each seat provides full functionality in
sliding and reclining. Check all available functions
of the rear seat such as a trunk-through center arm-
rest.
24.SEAT BELT
1) Check installation condition of seat belt.
2) Pull out the seat belt and then release it. Check
that the belt retracts smoothly.
25.WHEEL ALIGNMENT
Check the wheel alignment. <Ref. to FS-8, Wheel
Alignment.> <Ref. to RS-8, Wheel Alignment.>
Pre-delivery Inspection
26.TEST MODE CONNECTOR
Turn the ignition switch to ON and check that the
malfunction indicator light starts blinking. If the light
blinks, return the ignition key to LOCK. Pull out the
test mode connector from the back of glove box
lower cover, and disconnect the test mode connec-
tor. Then, turn the ignition key to ON again. If the
malfunction indicator light blinks at that time in spite
of the disconnected test mode connector, carry out
an engine diagnosis.
PI-00176
NOTE:
If it is difficult to pull out the test mode connector,
remove the glove box lower cover, and disconnect
the test mode connector.
PI-00196
27.IMMOBILIZER SYSTEM
1) Check that the engine starts with all keys that
are equipped on vehicle.
2) 60 seconds after turning the ignition switch from
ON to ACC or OFF, or immediately after removing
the key, check that the security indicator light blink-
ing.
NOTE:
If malfunctions occur, refer to "IMMOBILIZER (DI-
AGNOSIS)".
PI-10
(A)
(A) Test mode connector (green)
(B)
(A) Test mode connector (green)
(B) Glove box lower cover
PI-00201
(A)
PI-00197

Hide quick links: