Diagnostic Codes For Status Led; Fault Code History - Napoleon 9500 series Installation And Operating Instructions Manual

Single stage multi position high efficiency condensing forced air gas furnace
Table of Contents

Advertisement

50

19.4 DIAGNOSTIC CODES FOR STATUS LED

A 3 colour LED is provided to indicate system faults. LED codes are as follows:
IOM
IOM
• LED Off - No power to control, push button switch pressed, or control fault
• LED Steady On (any colour) - Control hardware fault detected
• Slow Green Flash - No call for heat, no active errors
• Slow Orange Flash - Call for heat present, no active errors
• Rapid fl ash - Incorrect 24VAC phasing/twinning errors

19.5 FAULT CODE HISTORY

The control stores the last 5 fault codes in memory. When the push button switch is pressed, the
control will fl ash the stored fault codes when the switch is released. The most recent fault code is
fl ashed fi rst, the oldest last.
Fault history may be cleared by holding the push button switch for more than 5 seconds.
W415-0973 / B / 08.28.13
STATUS
LED
Red LED indicates following codes:
LED OFF
No power to control or control hardware fault detected
LED ON
Normal operation
1 Flash
High limit switch open
2 Flashes
Pressure switch open with inducer on
3 Flashes
Pressure switch closed with inducer off
4 Flashes
Lockout due to too many failed ignition attempts (1 hour lockout)
5 Flashes
L1/Neutral Polarity problem
6 Flashes
Too many limit trips within one call for heat
7 Flashes
Pressure switch cycle lockout
8 Flashes
Lockout due to too many fl ame dropouts
9 Flashes
Not used
10 Flashes
Flame present with gas valve off
FAULT CONDITION
H23.4.1
H23.5

Hide quick links: