System Exclusive Message - Yamaha SY85 Owner's Manual

Hide thumbs Also See for SY85:
Table of Contents

Advertisement

2. System exclusive message

2.1 Parameter change
The SY85 transmits and receives the following eight parameter change types.
(7) Remote switch is received only.) 7) Remote switch will be the same as the screen when the switch is
pressed.
1). Multi Data
2). Performance Data
3). Normal Voice Data
4). Drum Voice Data
5). Setup Data
6). Program Change Table
7). Switch Remote
8). Master Tuning
The parameter change reception cannot be turned off with each MIDI switch, except for Device Number
off.
2.1.1 sy85 Data parameter change
(1)Format
11110000
F0
01000011
13
0001nnnn
nnnn
= Device Number
00101001
29
0000gggg
gggg
- Parameter Croup (lumber
0sssssss
sssssss = Parameter Sub Group Number
0ppppppp
ppppppp= Parameter Number MS7b it
0ppppppp
ppppppp= Parameter Number LS7bit
0vvvvvvv
vvvvvvv Data Value MS7bit
0vvvvvvv
vvvvvvv = Data Value LS7bit
11110111
F7
(2)Parameter Group Number,Sub Group Number
Parameter Group Name
Multi Data
Performance Data
Normal Voice Data
Drum Voice Data
Setup Data
Program Change Table
Switch Remote
*1:1..16; Inst Number, 0;common data
*2:1..4; Layer Number, 0;common data
*3:1..4 = Layer Number (Layer Voice Edit), 0 = Voice
*4:36..84 = Key Number,0;common data
*5:0=syn, 1 = seq. 2 = ry
*6:Program Number
(3) Parameter Number, Data Value
See the appended table 1.
(4) Operation
(Transmission)
When data is edited with the panel switch, the parameter change is transmitted in accordance with
the above transmission conditions,
(Reception)
1) ~ 4)
The SY85 has four sound generation modes: Voice, Performance, Multi, Wave. Only when the
sound generation mode of the transmitting side and receiving side match, it is received. The mode
on the receiving side does not change and the page does not move. However, the data display will
be updated.
5) ~ 6)
All modes: Modes are received as they are. (no page change)
7)
This parameter change is only for reception. Remote controlling is possible with all the panel
switches. This message has the same effect as pressing the switch.
sssssss
gggg
0
0,1..16
*1
1
0,1..4
*2
2
0,1..4
*3
3
0.36..84
*4
0..2
*5
4
5
0..63
*6
6
0
2.1.2
Master Tuning parameter change
(1)Format
11110000
F0
01000011
43
0001nnnn
nnnn
= Device Number
00101001
04
01000000
40
0vvvvvvv
vvvvvvv = Data Value
11110111
F7
(2) Operation
(Transmission)
When the master tune data is edited with the panel switch, the parameter change is transmitted in ac-
cordance with the above transmission conditions.
(Reception)
All modes: Modes are received as they are, (no page change)
3. Bulk dump
The SY85 transmits and receives the following ten bulk dump types.
Reception is not possible during performance and recording.
Transmission is performed when MIDI UTILITY bulk dump is executed, or when a dump request is
received.
1). Normal Voice bulk dump
2). Drum Voice bulk dump
3). Performance bulk dump
4). Multi(Song) bulk dump
5). Synthesizer Setup bulk dump
6). Seq Setup bulk dump
7). Sample bulk dump
8). Rhythm bulk dump
9). All Seq bulk dump
10). Nseq bulk dump
3.1.1
Bulk Dump 1)~7)
(1)Format
3

Advertisement

Table of Contents
loading

Table of Contents