9. Auto White Balance Standard Data Input

Adjust the white balance standard data at 3200K.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Refer to "Picture Frame Setting" for YH and YL.
Note 3: "Auto White Balance Standard Data Input" is available
only once after the power is turned on. Turn the power
off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
7
6
93
YH
8
6
01
79
9
6
07
10
6
01
00
11
6
01
11
12
6
01
0B
13
6
02
Note 4: The adjustment data will be automatically input to
page: F, address: 3A to 3D and 59.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
6
2C
00
3
6
92
00
4
6
93
00
5
6
0
01
00
CAMERA
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
F
3A to 3D, 59
Procedure
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
(Note 2)
(Note 2)
Press PAUSE button.
Check the data changes to "01".
Press PAUSE button.
Press PAUSE button.
Press PAUSE button. (Note 4)
Check the data changes to "01".
Procedure
Press PAUSE button.
Release the data setting
performed at step 2 .
(Refer to page 5-14)
– 13 –