Auto White Balance Adjustment - Sony Syber-shot DSC-S85 Service Manual

Digital still camera
Hide thumbs Also See for Syber-shot DSC-S85:
Table of Contents

Advertisement

10. Auto White Balance Adjustment

Adjust to the proper auto white balance output data. If it is not
correct, auto white balance and color reproducibility will be poor.
Mode
Subject
Filter
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Refer to "Picture Frame Setting" for YH and YL.
Note 3: The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Note 4: "Auto White Balance Adjustment" is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
4
6
2C
01
5
6
90
00
6
6
91
00
7
6
92
YL
8
6
93
YH
9
6
01
79
10
6
07
11
6
01
00
12
6
01
A7
49
4A
13
F
4B
4C
49
29
4A
80
14
F
4B
5E
4C
00
15
6
01
A5
16
6
02
17
6
01
3F
18
0
03
04
CAMERA
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Filter C14 for color temperature
correction
Displayed data of page: 1 (Note 3)
Adjusting remote commander
F
3F, 40, 80, A9, AA
R ratio: 28E0 to 2A20
B ratio: 5D60 to 5EA0
Displayed data
Procedure
Place the C14 filter on the lens.
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
(Note 2)
(Note 2)
Press PAUSE button.
Check the data changes to "01".
Press PAUSE button.
Press PAUSE button.
Note down the data.
Press PAUSE button.
Press PAUSE button. (Note 5)
Check the data changes to "01".
Press PAUSE button.
Order Page Address Data
19
1
20
0
03
21
1
22
6
01
23
6
01
24
6
13
25
6
01
26
6
02
Note 5: The adjustment data will be automatically input to
page: F, address: 3F, 40, 80, A9 and AA.
Processing after Completing Adjustment:
Order Page Address Data
1
0
03
2
6
01
3
6
13
4
6
2C
5
6
92
6
6
93
49
4A
7
F
4B
4C
8
9
0
01
10
– 14 –
Ver. 1.1 2001. 08
Procedure
Check that the displayed data
(Note 3)
satisfies the R ratio specified
value.
05
Check that the displayed data
(Note 3)
satisfies the B ratio specified
value.
00
Press PAUSE button.
11
Press PAUSE button.
AE
Press PAUSE button.
D3
Press PAUSE button.
Check the data changes to "01".
Procedure
00
00
Press PAUSE button.
00
Press PAUSE button.
00
00
00
Set the data noted down at
step 13, and press PAUSE
button.
Release the data setting
performed at step 3 .
(Refer to page 5-14)
00
Remove the C14 filter on the
lens.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cyber-shot dsc-s85

Table of Contents