Ic201 (Ba6247Fp-Y) Motor Driver Ic Operation - Sony XES-Z50 Service Manual

Digital reference sound system
Hide thumbs Also See for XES-Z50:
Table of Contents

Advertisement

7-2. IC201 (BA6247FP-Y) MOTOR DRIVER IC OPERATION

(DRIVER BOARD)
The elevator up/down motor connected between pin @™ and pin !• of IC201 is as M501, and the disc load/save motor connected
between pin 1 and pin !• of IC201 is as M502.
When the IC port logic is pin @™ > pin !•, pin 1 > pin !•, the rotating direction of M501 and M502 becomes normal.
ROTATION TRUTH TABLE
1 When MB=MC: both M501 and M502 are stop. (MA value is free.)
2 When MB≠MC:
Pin of IC301
MA
MB
(pin 8)
(pin 7)
"L"
"L"
"H"
"L"
"L"
"H"
"H"
"H"
Rotating direction
of motor
MC
M501
M502
(pin 6)
"H"
Reverse
Stop
"H"
Normal
Stop
"L"
Stop
Reverse
"L"
Stop
Normal
Disc load/save
1
M502
(1–18)
!•
Pin of IC201
pin @™
pin 1
"L"
OPEN
"H"
OPEN
OPEN
"L"
OPEN
"H"
Elevator up/down
!•
M501
(22–18)
@™
– 76 –
Operation
pin !•
"H"
Elevator up
"L"
Elevator down
"H"
Disc load
"L"
Disc save