Fault Finding - Stanley Donard Installation And Operating Instructions Manual

Solid fuel cooker
Table of Contents

Advertisement

1.
Poor Chimney Draught
2.
Excessive Chimney Draught
3.
Down Draught
4.
Cooker Smoking
5.
Hot Plate Not Heating
6.
Oven Not Heating
7.
Radiators Not Heating
8.
Domestic Hot Water Cylinder
not heating
9.
Intermittent Performance
10.
Domestic Hot Water Rusty
It is of the utmost importance to keep the flue pipe and chimney clear of deposits by regular sweeping of the
chimney irrespective of whether the fuel used is classed as smokeless or not. All fuels give rise to soot or ash
deposits and regular cleaning is essential for safe operation.
Blocked or partially obstructed flueways and chimneys will cause dangerous fumes to be emitted into the room,
these may well be invisible if a smokeless fuel is burned.
FAULT FINDINGS
(a) Obstruction
(b) Too Low
(c) Too Wide
(d) Crack in Wall
(e) Shared by another unit
(a) High Chimney
(a) High Trees
(b) High Buildings
(c) Negative Pressure Zone
(a) Insufficient Primary Air
(b) Chimney Choked
(c) Side Flueways Choked
(d) Down Draught
(a) Soot Under Hot Plate
(b) Fire too Low
(c) Utensils not Flat
(a) Poor Chimney Draught
(b) Flueways blocked with soot
(c) Damper open to Chimney
(d) Faulty Thermostat
(a) Pump not Working
(b) Air in Radiators
(c) Pipe System Faulty
(d) Excessive Number of Radiators
(e) Radiator Valves not adjusted
(a) Cylinder too Large
(b) Flow Pipe too small
(c) Flow Pipe crossed
(d) Cylinder too far away
(e) Hot water from boiler not
reaching cylinder
(a) Cooker starved of Primary Air
(b) Extraction Fan in room
(c) Cooker subjected to wind
change
(d) Dirty Flueways
(e) Poor Fire
(f) Uncontrolled Burning
(a) Leak in Indirect Cylinder Coil
(b) Incorrect Cylinder Fitted
16
(a) Clear and Clean
(b) Raise Height above Ridge
(c) Fit Flue Liner 15 to 23 c.m.
(d) Repair Cracks
(e) Cut of other Unit.
(a) Open Flue Cover of fit Draught Stabiliser
(a) Raise Chimney Height
(b) Raise Chimney Height
(c) Fit Cowl
(a) Provide Room Air Inlet
(b) Clean Chimney
(c) Clean Flueways
(d) Raise Chimney Height
(a) Remove and Clean
(b) Build better Fire
(c) Use machined based Utensils
(a) Raise Height or Fit Cowl
(b) Clean Out
(c) Close Damper
(d) Check and replace if necessary
(a) Check and replace if defective
(b) Vent Radiators
(c) Check Pipe Sizes and Circuit
(d) Turn off un-needed Radiators
(e) Adjust Valves to give even flow
(a) Use 135 - 180 L Cylinder
(b) Use 25mm Bore Pipe
(c) Reverse Flow Pipe
(d) Not more than 7.8m fully lagged.
(e) Adjust Flow Control Valves or
fit injector tee.
(a) Provided Air Inlet in Room.
(b) Provide additional Air Inlet in room
(c) Raise Chimney of Fit Cowl
(d) Clean Flueways Frequently.
(e) Burn more Fuel
(f) Repair or Replace Thermostat
(a) Replace Cylinder
(b) Check with installer