Fig. 13
C/L.
Rear Edge
200
200
Cut Out Hole
Minimum
from Wall
Top View of the Work top
Fig. 14
16 Installation
C/L.
85 Minimum
115
200
200
Maximum
Centre of
from Wall
the Flue
2. Attach the flue to the flue spigot.

Fitting under a Worktop (CFL Models)

1. Remove the top blanking plate from the
2. See Section 4.9 on page 28 of the
3. Remove the flue spigot from the
4. Mark the centre of the flue on the work top
5. Place boiler in position under the work
6. Re-fit the flue spigot as shown in Fig. 13.
7. Refit the products discharge safety device
135
Max.
100
100
Front Edge
This product is fitted with a combustion
products discharge safety device (TTB)
which must not be taken out of operation
at any time. The component is fitted to
ensure that any blockage or partial
blockage of the flue does not result in
combustion products discharging into the
room.
boiler (if already assembled).
Installation & Service Instructions,
remove the products discharge safety
device (TTB) and carefully place on top of
the appliance.
appliance by removing the 4 adjusting
screws.
and cut a 200 mm square hole from this
centre point. The centre point should be a
minimum of 85 mm from the wall and a
maximum of 135 mm from the wall being
dependent on the boiler position.
top.
(TTB) back onto the flue spigot and
secure with the screw.
IMPORTANT: Ensure the Products
Discharge Safety Device (TTB) is
repositioned correctly and secvured to
the dimension shown in Fig. 28, Page 29.
Publication No. 5102977