Operation
Selection
Selection
Selection
level 1
level 2
level 3
Installer
System
level
configura-
tion
1) Appears only if solar module VR 68/2 is connected.
2) Appears only if mixing module VR 61/2 is connected.
3) Appears only if mixing module VR 61/2 or solar module
VR 68/2 is connected.
4) Appears only if cylinder actoSTOR VIH RL is connected.
5) Appears only if remote control unit VR 81/2 is connected.
6) Appears only if no mixing module VR 61/2 is connected.
* If there is no fault, then the status is "OK". If there is a fault,
"Fault" appears here and you can read the error message
(¬ Section 10.2) here.
24
Setting level
Values
min.
Domestic hot water
Cylinder
Inactive
Cylinder temp.
35
target
Cyl. temp. current
Current value
Cylinder charge
Current value
pump
Circulation pump
Current value
Anti-legionella day
Anti-legionella time
0:00
Cylinder boost
15
3)
offset 
Load pump
0
2)
Paral. cyl. charge 
Off
LP/ZP relay
2)
connection 
Unit
Step size,
select
max.
Active
Active,
inactive
70
°C
1
°C
On, Off
On, Off
Mon, Tue, Wed,
Thu, Fri, Sat,
Sun,
Off,
Mon-Sun
23:50
hr:min
10 min
40
K
1
10
min
1
On
Off, On
no connect.,
Circ. pump,
Charg.pump
Installation instructions VRC 470 0020116690_00
Factory
Own setting
reset
Active
60
Off
4:00
25
5
Off
no con-
nect.