Table 3-22
QuickFind Diagnostic Panel LED Definitions (Continued)
Item
LED 0
Memory
DIMM xA DIMM xB DIMM xC DIMM xD The specified DIMM has failed—reseat or
bank X (0-7)
Check power
n/a
supply
Memory
n/a
config error
Processor
n/a
config error
Missing
n/a
component
System temp n/a
Check event
n/a
log
142
LED1
LED2
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
LED3
replace the memory board and DIMM.
If all the LEDs for a rank (0-7) are lit and the
memory config error LED is lit, then the
DIMMs in the specified rank are
mismatched—review the information on
installing memory.
The faulty power supply LED (located on
Power supply) is lit. Reseat the power supply.
The DIMMs in a rank are
mismatched—review the information on
installing memory.
The processors are mismatched—review the
information on installing processors.
A required component(s) is not detected.
Check that recently installed items are
correctly installed.
Make sure nothing is blocking server airflow.
Check that recently installed items are
correctly installed.
An event has occurred that requires
attention.