JVC GY-DV5000 Instructions Manual page 89

Dv camcorder
Hide thumbs Also See for GY-DV5000:
Table of Contents

Advertisement

Viewfinder Warning Lamps
1.
BATT
ALARM
Battery lamp
Alarm Sound
When remaining battery power becomes low, a warning
sound is output from the monitoring loudspeaker and the
PHONES jack. (In Camera mode only)
When an irregularity occurs in the VCR, a warning sound is
also output.
Depending on the alarm conditions, the warning indicators on the LCD monitor/viewfinder screen, the TALLY lamp, the viewfinder
lamp, and alarm sounds appear as shown in the following table.
Alarm Indications
on LCD Monitor/
Viewfinder Screen
VTR alarm indication
(Example)
0701
DRUM MOTOR FAILURE
HEAD CLEANING
REQUIRED!
TAPE NEAR END
LOW VOLTAGE
and Voltage indication on
Status screen blinks
Display symbols
:Blinking once per second.
:Sound interrupted once per second.
2.
REC
REC/ALARM lamp
Lamp Viewfinder Lamp
TALLY
Lamp
Alarm
BATT
1.
BATTERY lamp
This red lamp lights red under the following circumstances.
Lights red : When the battery voltage becomes too low for
the camera to operate.
2.
REC/ALARM lamp
This lamp lights or blinks green under the following
conditions.
Lights Green : ● While recording
Blinks Green : ● During the interval where the unit
● Immediately before the tape runs out or
● If the VCR malfunctions.
Whether or not alarm sound should be output and the
volume level are selected with the ALARM VR LEVEL item
on the OTHERS (2/2) menu screen.
Alarm Sound
:Blinking four times per second.
:Continuous sound.
13. OTHERS
switches from record-standby to record
mode.
has run out.
Condition
Dew formation (condensation) or error
has occurred in the VCR.
Video head clogging [Detected and
displayed during playback and edit search
in the Camera mode.]
About 3 min. before tape end
(displayed during recording).
Tape end
(displayed during recording).
Remaining battery power is low.
89