Kidde SL177i User Manual page 5

120vac dual mode strobe light for the hearing impaired
Hide thumbs Also See for SL177i:
Table of Contents

Advertisement

Multiple station (24) interconnect unit, interfaces directly with Kidde Safety
Ion Smoke Alarm models:
Photo smoke alarms:
Photo / Ion smoke alarms:
Heat Alarm models:
CO/ Ion Smoke alarm models:
Carbon Monoxide Alarms Model:
-
FLASH RATE (smoke alarm event)
FLASH RATE (CO alarm event)
MODEL NUMBER
ELECTRICAL RATING
Note: This device was only tested over the range 110-130 VAC. Do not take 80% and110% of these
ratings into account during installation as this was not tested for.
FLASH RATE
MODEL NUMBER
TEMPERATURE LIMITS
MOUNTING
APPLICATIONS
LIGHT OUTPUT
The following diagram shows that the light intensity gradually decreases as the Viewing angle is
increased. Use this information to determine the best location for the strobe light.
90°
90°
45°
45°
LIGHT
LIGHT
SOURCE
SOURCE
CEILING
CEILING
90°
90°
45°
45°
1235, 1235CA, 1275, 1275CA, 1285, 1285CA
PE120, PE120CA,
PI2000, PI2000CA
HD135F, HD135FCA
KN-COSM-IB , KN-COSM-IBCA
KN-COB-IC, KN-COP-IC
Constant 1 flash per second nominal
Intermittent 1 flash per second nominal (approximately 4
flashes, followed by approximately 5 seconds OFF)
SL177 ( 2 WIRE DIRECT CONNECT UNIT )
Special Application 110-130 VAC
Maximum Operating RMS Current 389 mA
Constant 1 flash per second nominal
SL177I & SL177
32 o F (0 o C) TO 120 o F (49 o C)
Wall or Ceiling,
Primary Direct or Indirect and Supplementary
177 Candela minimum. (on axis measurement)
PERCENT
PERCENT
ANGLE
ANGLE
(LIGHT INTENSITY)
(LIGHT INTENSITY)
(IN DEGREES)
(IN DEGREES)
100
100
0
0
90
90
5-25
5-25
75
75
30-45
30-45
55
55
50
50
45
45
55
55
40
40
60
60
35
35
65
65
35
35
70
70
30
30
75
75
30
30
80
80
25
25
85
85
25
25
90
90
90°
90°
45°
45°
LIGHT
LIGHT
SOURCE
SOURCE
WALL
WALL
45°
45°
90°
90°

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl177

Table of Contents