Control Channel Functions

The following control actions must be accomplished with zero time transition or with timing disabled.
Discrete values must be used and not manual controls such as faders or encoders.
To use control channel functions:
Step 1. Select an action to be sent.
Step 2. Set control channel value for desired action (for example, 84 for reset). Hold value for 3
seconds.
Note: A numerical keypad is required for sending values. An encoder or fader does not allow for a
"snap" value change, which is required to affect the control functions.
Step 3. Set control channel value to zero. (This must occur without any scaling values. Action will
be voided if other values are detected between action value and zero.)
The following pages contain the control channel function maps for the VL440 spot, VL770 spot, and
VL880 spot luminaires. Refer to the corresponding control channel functions table for your fixture.
Control channel information is segregated into four sections:
"VL440 Spot Control Channel Functions" on page 56
"VL770 Spot Control Channel Functions" on page 57
"VL880 Spot Control Channel Functions" on page 58
02.96 87.000 1 0
Table 14: Timing Channels Map (Continued)
DMX
245
246
247
248
249
250
251
252
253
254
255
26 J uly 20 11
O
: L
PERATION
% Value
96
97
98
99
100
T
UMINAIRE
IMING
= Seconds
280
290
290
290
300
300
310
310
310
310
Follows Cue Data
3
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents