Detailed Description Of Maintenance-Mode Functions; Eeprom Parameter Initialization - Brother FAX4759 Service Manual

Table of Contents

Advertisement

3. DETAILED DESCRIPTION OF
MAINTENANCE-MODE FUNCTIONS
3.1

EEPROM Parameter Initialization

n n
Function
The equipment initializes the parameters, user switches, and firmware switches registered in the
EEPROM, to the initial values. Entering the function code 01 initializes all of the EEPROM areas,
but entering 91 does not initialize some areas, as listed below.
Data item
Maintenance-mode functions
User switches
Firmware switches
Remote activation code
Activity report
Station ID data
Outside line number
Telephone function registration
One-touch dialing
Speed dialing
Group dialing
Received FAX messages
temporarily stored in the flash
memory (Not applicable to the
American version)
EEPROM customizing code
(4-digit)
NOTE: If you replace the main PCB with one used for other facsimile equipment, carry out this
procedure and then customize the EEPROM (maintenance-mode function code 74 in Subsection
3.11).
n n
Operating Procedure
(1) Press the 0 and 1 keys (or the 9 and 1 keys according to your need) in this order in the initial
stage of the maintenance mode.
The "PARAMETER INIT" will appear on the LCD.
(2) Upon completion of parameter initialization, the equipment returns to the initial stage of the
maintenance mode.
Function code
(Note that the first digit of the 4-digit customizing
code will be initialized to "0." If the code is 1001, for
example, it will be initialized to 0001.)
V - 4
01
All of these will be.
initialized
These will not be initialized.
91
These will be
initialized
These will not be
initialized