Level Diagram - Kenwood TK-7100 Service Manual

Vhf fm transceiver
Hide thumbs Also See for TK-7100:
Table of Contents

Advertisement

TK-7100
Receiver Section
W : –123.5dBm
N : –123.0dBm
ANT
BPF
Transmitter Section
Display
Unit
X54-343
MIC
To make measurements in the AF section, connect the AC level meter.
AG is set so that MIC input becomes 3kHz/1.5kHz (Wide/Narrow) DEV at 1kHz MOD.
48

LEVEL DIAGRAM

Center Frequency
W : –119.0dBm
W : –104.5dBm
N : –118.5dBm
N : –103.5dBm
Q353
D
G2
BPF
G1
S
W/N
5.0mVrms
W/N
W/N
0.10Vrms
1.40Vrms
IC201
IC201
2
1
6
7
W : –104.0dBm
N : –103.5dBm
Q352
D
G2
G1
S
To make measurements in the RF section, connect the RF level meter.
In the RF section, use a 0.01µF coupling capacitor.
(The display shows the SSG input value required to obtain 12dB SINA
TX-RX Unit
W/N
W/N
1.16Vrms
1.26Vrms
IC202
IC202
3
1
5
7
49.95MHz
W : –77.5dBm
N : –74.0dBm
W : –112.0dBm
W : –92.0dBm
N : –111.5dBm
N : –90.5dBm
XF1
Q351
W/N
W : 1.05Vrms
W : 0.49Vrms
1.04Vrms
N : 0.44Vrms
N : 0.20Vrms
IC203
IC203
2
1
9
8
450kHz
CF1
/CF2
IC301
20
TX-
IC161
Q40
9
10
To ma