10.1.3 Temperature-setting adjustments
Setting the domestic hot water (DHW) temperature (in
combination with an external hot water cylinder)
Press E button (see fig. 6, item 2) once then adjust the
DHW temperature to the desired temperature (40 °C -
60 °C) using the C and D keys (see fig. 6, item 1).
Factory setting is 48 °C.
Setting the boiler to summer operation
When you want to make sure that your boiler will not operate
for central heating in the summer then you can set the boiler to
summer operation. The boiler will then only operate for DHW
(in combination with an external hot water cylinder).
Press the E button (see fig. 6, item 2) twice.
The current setting blinks.
Use the C and D keys to adjust to desired setting.
Central heating is on.
Central heating is off (summer operation).
DHW is still available (in combination with an
external hot water cylinder).
NOTE
When summer operation is active then the
boiler will not operate for central heating until
summer operation has been deactivated.
Setting the flow temperature for CH
Press E button (see fig. 6, item 2) three times then adjust
the flow temperature to the desired temperature (30 °C –
80 °C) using the C and D keys (see fig. 6, item 1).
Factory setting is 80 °C.
It is not possible to set the flow temperature when the boiler is
set to summer operation.
10.2

Operational and fault codes

Operating conditions and possible faults can be seen, pressing
the C key.
All codes not contained in table 1 should be noted down
separately. These are malfunctions that require the presence
of a CORGI installer.
Buderus • http://www.buderus-domestic.co.uk
8
fig. 6
DBA – control panel
Display after
pressing
Meaning
service
button
0A, 0C, 0E,
Boiler is ready for
0H, 0L, 0U,
operation
0Y
6A
Burner not ignited
Normal heating
-H
mode
Normal hot water
=H
mode
Tab. 1
Operational and fault codes
Subject to modifications resulting from technical improvements!
Users manual for Buderus 500 - 24/S • edition 02/2006
1
2
3
Rectification
B
Press Reset button
(fig.
6, item 3). If the
burner fails to ignite after
several unblocking opera-
tions, consult a CORGI
installer.