The purpose of calibration is to heighten the dimensional accuracy of the x-axis and y-
axis measurements produced by your Summit marker plotter.
To calibrate your Summit marker plotter:
1.
Turn on the Summit.
2.
Press "Starting Point" and then "Pause" to place the Summit online.
3.
From your computer open the Ioline Control Center software that was originally
provided with your machine.
4.
From the main menu select "Calibrate" then "Calibrate Plotter".
Calibration" window should appear.
5.
Before calibrating, reset your Summit's "Calibration Setting" to its factory default
(1.0000), click on "Reset Calibration".
6.
Install media large enough for the calibration plot. 41" X 48" (104 cm X 122
cm).
7.
Click on "Calibration Plot" to plot the stored calibration plot. Your Summit will
draw four ruled lines, two in each axis. In the X-axis 40" and 101 cm. In the Y-
axis 46" and 116 cm.
8.
Precisely measure one length and one width line (inches or centimeters) and
record your results.
9.
Accurately enter the measured values in the fields labeled "Measured" for both x
and y.
10.
Click on "Set Calibration".
11.
Your Summit will calibrate itself, and the new "Calibration Setting" will be
displayed.
12.
Click on "Done" when you are finished.
Dimensional Calibration/Summit