LENNOX CRESTLINE™ SERIES B-VENT GAS FIREPLACES • 36"/42" LSBV MODELS • INSTALLATION INSTRUCTIONS
Test gage connections are provided on the front
of the millivolt gas control valves (identified OUT
for the manifold side and IN for inlet pressure side.
Nominal operating pressures for the manifold
side of the gas control system are; 3.5 inches
water column (0.87 kPa) for natural gas models
and 10 inches water column (2.49 kPa) for
propane gas models.
Minimum inlet gas pressure to the appliance is
5.0 inches water column (1.24 kPa) for natural
gas and 11 inches water column (2.74 kPa) for
propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to the ap-
pliance is 10.5 inches water column (2.61kPa)
for natural gas and 13.0 inches water column
(3.23 kPa) for propane. The appliance must
be isolated from the gas supply piping system
(by closing its individual manual shut-off valve)
during any pressure testing of the gas supply
piping system at test pressures equal to or less
than 1/2 psig (3.5) kPa).
The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of 1/2 psig
(3.5 kPa).

LOCATION

Typical Locations
Figure 1
In selecting the location, the aesthetic and func-
tional use of the appliance are primary concerns.
However, vent system routing to the exterior and
access to the fuel supply are also important. Due
to high temperatures the appliance should be
located out of traffic and away from furniture and
draperies. Consideration should be given to traffic
ways, furniture, draperies, etc., due to elevated
surface temperatures. The location should also
be free of electrical, plumbing or other heating/
air conditioning ducting.
4

APPLIANCE SPECIFICATIONS

7-3/32
28-15/32
LSBV-36: 37
5-3/4
LSBV-42: 43
Gas Line
Or Switch
Wire Outlet
1-7/16
8-7/8
Left Side View
8-15/32
Figure 2
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
12-15/32
LSBV-36: 41-3/4
LSBV-42: 47-3/4
Front View
7-7/16
Gas Line
15-27/32
Or Switch
Wire Outlet
1-25/32
Right Side View
LSBV-36: 23-1/2
LSBV-42: 29-1/2
Top View
52-11/32
47-9/32
41-5/16
Combustion
Air Inlet
Junction
Box
Location
4-13/32
2-9/32
16-1/16
20-1/32
19/32