Table Of Contents; Packaging; Introduction - Lennox Crestline LSBV-3628MN Installation Instructions Manual

Crestline series b-vent gas fireplaces 36"/42" lsbv models
Table of Contents

Advertisement

LENNOX CRESTLINE™ SERIES B-VENT GAS FIREPLACES • 36"/42" LSBV MODELS • INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS

Packaging .........................................page
Introduction ......................................page
General Information ..........................page
Location ............................................page
Appliance Specifications ...................page
Clearances ........................................page
Gas Vent Rule ...................................page
Framing Specifications ......................page
Assembly Steps ................................page
Installation ........................................page
Vent System Installation ...................page
Field Wiring .......................................page
Connecting Gas Line .........................page
Outside Air Kit Installation .................page
Log and Glowing Embers
Installation ...................................page
Appliance Operation ..........................page 10
Manual Limit Switch .........................page 10
Millivolt Appliance Checkout .............page 11
Adjustment ........................................page 11
Finishing Requirements ....................page 12
Cold Climate Insulation .....................page 12
Installation Accessories ....................page 14
Gas Conversion Kits .................. page 15
Please read and understand these
instructions before beginning your
installation.

PACKAGING

The assembled vented gas fireplace is packaged
with the following items:
• One foam packaged log set located in firebox
area.
• One bag of glowing embers (rockwool)
located in the bottom compartment.
• One envelope containing the literature pack-
age, which consists of the homeowner's
manual, installation instructions, and war-
ranty. Envelope is located in the control area.
2

INTROdUCTION

The millivolt appliances are designed to operate
2
on either natural or propane gas. A millivolt gas
2
control valve with piezo ignition system provides
safe, efficient operation.
3
The electronic appliances are designed to
3
operate on either natural or propane gas. An
4
electronic intermittent pilot system provides
safe, efficient operation. External electrical
4
power is required to operate these units.
5
5
These appliances comply with National Safety
Standards and are tested and listed by Omni-
5
Test Laboratories (Report No. 116-F-45-5) to
6
ANSI Z21.50b (in Canada, CSA-2.22b), and
6
CAN/CGA-2.17-M91 in both USA and Canada,
7
as vented gas fireplaces.
7
Installation must conform to local codes. In
8
the absence of local codes, installation must
8
comply with the current National Fuel Gas Code,
ANSI Z223.1 (NFPA 54) (in Canada, the current
CAN/CGA B149 installation code). Electrical
9
wiring must comply with local codes. In the
absence of local codes, installation must be in
accordance with the National Electrical Code,
NFPA 70, latest edition (in Canada, the current
CSA C22.1 Canadian Electric Code).
These Crestline series appliances have been
designed, tested and listed for use with Security
Chimney's 10" B-vent system. Refer to page 14
for a complete listing of the 10" B-vent com-
ponents available for use with these models.
WARNING
B-Vent appliances are not
designed to operate in negatively
pressured environments (pres-
sure within the home is less than
pressures outside). Significant
negatively pressured environ-
ments caused by weather, home
design, or other devices may
impact the operation of these
appliances.
Negative pres-
sures may result in poor flame
appearance, sooting, damage to
property and/or severe personal
injury. Do not operate these
appliances in negatively pres-
sured environments.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNING
Young children should be care-
fully supervised when they are
in the same room as the appli-
ance. Toddlers, young children
and others may be susceptible
to accidental contact burns. A
physical barrier is recommended
if there are at risk individuals in
the house. To restrict access to
a fireplace or stove, install an
adjustable safety gate to keep
toddlers, young children and
other at risk individuals out of
the room and away from hot
surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être
surveillés étroitement lorsqu'ils
se trouvent dans la même pièce
que l'appareil. Les tout petits,
les jeunes enfants ou les adultes
peuvent subir des brûlures s'ils
viennent en contact avec la sur-
face chaude. Il est recommandé
d'installer une barrière physique
si des personnes à risques habi-
tent la maison. Pour empêcher
l'accès à un foyer ou à un poêle,
installez une barrière de sécu-
rité; cette mesure empêchera les
tout petits, les jeunes enfants et
toute autre personne à risque
d'avoir accès à la pièce et aux
surfaces chaudes.
Children and adults should be alerted to the
hazards of high surface temperature and
should stay away to avoid burns or clothing
ignition.
Les enfants et les adultes devraient être infor-
més des dangers que posent les températures
de surface élevées et se tenir à distance afin
d'éviter des brûlures ou que leurs vêtements
ne s'enflamment.
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.

Advertisement