Electrical Data - York YAST026 Installation Manual

Affinity outdoor split geothermal heat pumps dual capacity 2thru 6 nominal tons
Table of Contents

Advertisement

Electrical Data

Rated
Model
Voltage
026
208-230/60/1
038
208-230/60/1
049
208-230/60/1
064
208-230/60/1
072
208-230/60/1
Rated voltage of 208-230/60/1.
HACR circuit breaker in USA only.
Min/Max voltage of 187/253.
All fuses Class RK-5
* With optional GeoStart
Voltage
Min/Max
MCC
RLA
187/253
18.2
11.6
187/253
23.8
15.2
187/253
33.0
21.1
187/253
42.3
27.1
187/253
46.3
29.6
AFFINITY DUAL-CAPACITY OUTDOOR SPLIT SERIES INSTALLATION MANUAL
Compressor
LRA
LRA*
58.3
21.0
83.0
30.0
104.0
37.0
152.9
54.0
179.2
63.0
13
Ext
Total
Min
Loop
Unit
Circ
FLA
FLA
Amp
5.4
17.0
19.9
5.4
20.6
24.4
5.4
26.5
31.8
5.4
32.5
39.3
5.4
35.0
42.4
Max
Fuse/
HACR
30
40
50
70
75
7/10/13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yast072Yast038Yast049Yast064

Table of Contents