Samsung CLX-3185 Service Manual page 41

Clx-3185 series digital color laser mfp
Hide thumbs Also See for CLX-3185:
Table of Contents

Advertisement

1) Charger Voltage : Charger
• Function: voltage that charges OPC surface up to -500V~ -800V.
• Output voltage: -1.0KV ~ -2.0KV DC 3%
• Error type: if the voltage fails to be output to Charger Roll, OPC surface will not be charged, and the
toner on the developer roller will be transferred to OPC Drum, printing black paper.
2) 1st Transfer High Voltage : T1(+)
• Function: voltage necessary for transferring toner developed on OPC Drum surface onto ITB.
• Output voltage: Max +2.0KV 3%(Duty variable, no load)
• ERROR type: if T1(+) output fails, the toner on OPC drum will not be transferred to ITB normally and the
image will be blurred.
3) 2nd Transfer High Voltage : T2(+)
• Function: voltage used to transfer the toner primarily transferred on ITB again onto paper.
• Output voltage: Max +5.0KV 3%(Duty variable, no load)
• ERROR type: if T2(+) output fails, the toner on ITB will not be transferred to paper normally and the
image will be blurred.
4) T2 Cleaning Voltage : Clean : T2(-)
• Function: prevent reverse side of paper from being dirtied, by recovering the negatively charged toner
remaining at Transfer Roller and sending it onto ITB.
• Output voltage: with no feedback control, output fixed voltage(-1300V 15%)
• ERROR type: reverse side of paper will be dirtied.
5) Supplying Voltage : Supply AC+DC(-)
• Function: voltage that makes toner to develop on the area exposed by LSU by means of potential
difference, output will be the voltage of AC+DC overlapped form.
• Output voltage: AC 600V ~ 2000V p-p 1.5%
DC -50V ~ -600V DC 3%
• ERROR type: 1. if supply is GND, density will be extremely low.
2. if supply is floating (for insecure terminal contact), density will be down so slightly that it
is impossible to make out with naked eyes.
6) Developing Voltage : Deve AC+DC(-)
• Function: voltage that supplies toner to Developing Roller
• Output voltage: AC 250V ~ 1650Vp-p 1.5% (supply voltage is connected to ZENER Diode 350V)
DC -50V ~ -600V DC 3%
• ERROR type: 1. if Deve is GND, density will be extremely down.
2. if Deve is floating (for insecure terminal contact), density will be extremely down.
Service Manual
Product spec and feature
2-32
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clx-3185nClx-3185wClx-3185fnClx-3185fw

Table of Contents