e. A damper stop clamp with set screw is provided to pre-
vent full closure of the fi replace damper blade. Attach
the clamp to the edge of the damper blade with pliers
or wrenches. If the damper stop supplied does not fi t
the application, use a permanent means that will keep
the damper open to a MINIMUM of 51 square inches
(328cm
). See Figure 1.
2
WARNING! Risk of Fire!
Open the chimney damper to its FULLY OPEN posi-
tion when burning this gas log set.
DO NOT burn Logs without the fl ue damper in the
FULL OPEN position. Failure to do so is dangerous to
your health and voids all warranties.
Figure 1.
Note: The Commonwealth of Massachusetts requires that
the chimney fl ue damper, when used with gas logs, shall be
welded open or completely removed.
f. Test fi re the unit after referring to the SAFETY INFOR-
MATION and LIGHTING INSTRUCTIONS found in
Section 3 in this manual, or on the label plate assembly
found on the gas-burner.
g. After the gas line installation is complete, all connections
must be tightened and checked for leaks with a com-
mercially-available, non-corrosive leak check solution.
Be sure to rinse off all leak check solution following
testing. Refer to Section 3, OPERATING GUIDELINES
and MAINTENANCE INSTRUCTIONS.
h. Once the gas-burner is test fi red and gas supply lines
are purged, assemble the grate(s) and logs. Be certain
to follow the Log Placement Instructions shipped with
the unit. Remember to keep the Log Instructions along
with this manual for future use.
8
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, ST-CFL-24-B • 526-910 Rev. L • 11/14
DAMPER CLAMP
OPEN DAMPER
2. ELECTRICAL INSTALLATION
This appliance may be used with a wall switch and/or
remote control.
Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch.
• Keep wire lengths as short as possible by removing any
excess wire length.
Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
IGNITION MODULE 3 VAC
BATTERY PACK
(BATTERIES REQUIRED)
REMOTE OR
WALL SWITCH
Figure 2. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI
BLACK
REMOTE
OR WALL
SWITCH
RED
THERMOPILE
WHITE
Figure 3. Standing Pilot Wiring Diagram
INTERMITTENT PILOT IGNITOR
I
S
WHITE
ORANGE
GROUND TO
FIREPLACE
CHASSIS
WIRES
(TO BROWN)
VALVE
BLACK
ON/OFF
SWITCH