CAUTION: Provide a circuit breaker between power source and the unit
as shown below.
Main power source
Air
Conditioner

Connect the cable to the indoor unit

1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
• Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively.
2. Attach the Grille onto the cabinet.
• Grasp the lower left and right side of the
Grille and engage four tabs on the top inside
edge of the chassis.
• Press the Grille toward the chassis until it
will be back into place.
Connecting the Cable between Indoor Unit and Outdoor Unit
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
Power source Fuse or breaker
Model
Capacity
18K
1ø,230/208V
24K
1ø,230/208V
36K
1ø,230/208V
Connecting cable
Installation Manual 17
15A
20A
30A

Advertisement