■ Other Setup
● Alarms
To trigger alarms, setup the alarm source devices and register them to Alarm Source database by using Admin
Console.
# Alarm Type
1 Camera Motion
2 I/O Port (Dry con-
tact) alarm
3 RS232C alarm
4 Video Loss (any)
5 Video Loss (cam)
6 Global Alarm
7 Scene change
detection
8 Command alarm
9 Communication
Error (between cam-
era and recorder)
10 Intruder detection
11 Object detection
12 Capacity Warning
13 RAID Down
14 Thermal Error
15 DVR Error
(any of DVR Error)
16 Face Matching
28
Alarm Source
analog camera
network camera
analog digital input port in
SX850 or SX650 cage
network device
(network camera,
network decoder, DVR)
External system's RS232C
I/F
One of analog cameras via
SX850 or SX650 cage
A certain analog camera via
SX850 or SX650 cage
Other domains alarms and
do not care about alarm type
WV-NP1000
WV-NP1004
WV-NW484S
network camera
DVR (except RT416)
WJ-NT314
WJ-NT314
DVR (except RT416)
DVR (except RT416, ND200) 1. Set the Port number 1818 for Panasonic alarm.
DVR (except RT416)
DVR (except RT416)
WJ-NV200
How to setup
Turn on MOTION DET setting in dedicated camera
menu.
1. Select ON for network device's VMD alarm.
2. S et the Server IP Address to network devices'
alarm notification destination IP Address field.
Also set the port number 1818.
Select SX850 or SX650 node and Register the input
port setting to Admin I/O Ports menu
1. Select ON for network devices' Terminal alarm.
2. S et the Server IP Address to network devices'
alarm notification destination IP Address field.
Also set the port number 1818.
Select RS232 Controller Model for desired port in
Admin Controllers menu
Turn on Alarm Trigger check box in Admin Cameras
menu.
Turn on Alarm Trigger check box in Admin Cameras
menu.
Select one or more than one domain that the global
alarm should be exported in Admin Alarms menu,
Export tab, UNIT partition menu.
1. S elect ON for NP1000's Scene change detection
alarm.
2. S et the Server IP Address to NP1000's alarm noti-
fication destination IP Address field. Also set the
port number 1818.
1. Select ON for network devices' Command alarm.
2. S et the Server IP Address to network devices'
alarm notification destination IP Address field.
Also set the port number 1818.
1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
See the NT314 Network Operating Instructions.
See the NT314 Network Operating Instructions.
1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
3. Activate the face matching alarm action.
Alarm source setup in
Admin Console
Select Motion (cam)
Select I/O Port
Select I/O Port
Select RS232
Select Vid Loss (any)
Select Vid Loss (cam)
Select Global Alarm
Select Scene Change
(cam)
Select Cmd Alm (cam)
Select Comm Err (cam)
Select Intruder (cam)
Select Object dct.
(cam)
Select Capacity Warn
(dvr)
Select RAID Down
(dvr)
Select Therm Err (dvr)
Select DVR Err (dvr)
Select Face Match
(NV200)

Hide quick links: