10-2-20 Comp Vlimit error

Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the IPM Shunt("A") resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Is the Comp Vlimit error occurred again?
indoor/outdoor temperature
Samsung Electronics
LED3
LED OFF
Restart after power off.
Is the O.C error occurred?
YES
Is the connection
of compressor wire is
normal?
YES
YES
Is the condition of
normal load?
YES
7-SEG DISPLAY
E465
Comp V_limit/I_limit Error
NO
Terminate the service
NO
Connect the comp wire normally
NO
Terminate the service
NO
Restart after returning to the normal load
Is the O.C error
YES
occurred again?
DESCRIPTION
Comp V_limit/I_limit Error
MODEL
"A"
AR12(09)HSFSHWK
R410,R411,R412
AR18HSFSHWK
R413,R414,R415
Terminate the
NO
service
10-23